0.6/1kv AL/XLPE/PVC Aluminum Power Cable
Application
The 0.6/1kv Xlpe insulated Pvc sheathed aluminum power cable are used for power distribution in power stations, industrial installation and switchgears, as well as in local mains. Able to bear certain traction during installation. For fixed installation underground.
Constrution
Characteristics
Rated voltage | 0.6/1kV |
Conductor | Aluminum |
Insulation | XLPE |
Sheath | PVC |
Core | 1, 2, 3, 4, 5, 3+1, 3+2, 4+1 |
Color | Black or Customized |
Standards
GB/T 12706、IEC、BS、DIN and ICEA upon request
Parameters
2 Core Aluminum Power Cable |
||||||||
Nom. Cross-section of conductor |
Insulation Thickness |
Sheath Thickness |
Approx. O.D. |
Approx Weight |
Max. D.C. Resistance of Conductor (20°C) |
Test Voltage A.C |
Current Rating |
|
mm2 |
mm |
mm |
mm |
kg/km |
Ω/km |
kV/5min |
In air(A) |
In soil(A) |
2x4 |
0.7 |
1.8 |
11.4 |
150 |
7.41 |
3.5 |
34 |
45 |
2×6 |
0.7 |
1.8 |
12.4 |
171 |
4.61 |
3.5 |
43 |
57 |
2×10 |
0.7 |
1.8 |
14.9 |
238 |
3.08 |
3.5 |
60 |
77 |
2×16 |
0.7 |
1.8 |
17.1 |
294 |
1.91 |
3.5 |
83 |
105 |
2×25 |
0.9 |
1.8 |
20 |
394 |
1.2 |
3.5 |
105 |
125 |
2×35 |
0.9 |
1.8 |
22 |
484 |
0.868 |
3.5 |
125 |
155 |
2×50 |
1 |
1.8 |
23.4 |
497 |
0.641 |
3.5 |
160 |
185 |
2×70 |
1.1 |
1.8 |
24.5 |
640 |
0.443 |
3.5 |
200 |
225 |
2×95 |
1.1 |
1.9 |
28.6 |
827 |
0.32 |
3.5 |
245 |
270 |
2×120 |
1.2 |
2 |
29.7 |
1015 |
0.253 |
3.5 |
285 |
310 |
2×150 |
1.4 |
2.2 |
31.2 |
1268 |
0.206 |
3.5 |
325 |
345 |
3 Core Aluminum Power Cable |
||||||||
Nom. Cross-section of conductor |
Insulation Thickness |
Sheath Thickness |
Approx. O.D. |
Approx Weight |
Max. D.C. Resistance of Conductor (20°C) |
Test Voltage A.C |
Current Rating |
|
mm2 |
mm |
mm |
mm |
kg/km |
Ω/km |
kV/5min |
In air(A) |
In soil(A) |
3×4 |
0.7 |
1.8 |
12 |
163 |
7.41 |
3.5 |
34 |
45 |
3×6 |
0.7 |
1.8 |
13 |
191 |
4.61 |
3.5 |
43 |
57 |
3×10 |
0.7 |
1.8 |
15.8 |
282 |
3.08 |
3.5 |
60 |
77 |
3×16 |
0.7 |
1.8 |
18.2 |
358 |
1.91 |
3.5 |
83 |
105 |
3×25 |
0.9 |
1.8 |
21.3 |
491 |
1.2 |
3.5 |
105 |
125 |
3×35 |
0.9 |
1.8 |
23.6 |
600 |
0.868 |
3.5 |
125 |
155 |
3×50 |
1 |
1.8 |
23.8 |
729 |
0.641 |
3.5 |
160 |
185 |
3×70 |
1.1 |
1.9 |
27.4 |
958 |
0.443 |
3.5 |
200 |
225 |
3×95 |
1.1 |
2 |
33.1 |
1242 |
0.32 |
3.5 |
245 |
270 |
3×120 |
1.2 |
2.1 |
34.7 |
1502 |
0.253 |
3.5 |
285 |
310 |
3×150 |
1.4 |
2.3 |
39.1 |
1875 |
0.206 |
3.5 |
325 |
345 |
3×185 |
1.6 |
2.4 |
42.3 |
2264 |
0.164 |
3.5 |
375 |
390 |
3×240 |
1.7 |
2.6 |
47.8 |
2861 |
0.125 |
3.5 |
440 |
450 |
3×300 |
1.8 |
2.8 |
52.4 |
3501 |
0.1 |
3.5 |
505 |
515 |
3×400 |
2 |
3.1 |
62.9 |
4627 |
0.0778 |
3.5 |
570 |
575 |
4 Core Aluminum Power Cable |
||||||||
Nom. Cross-section of conductor |
Insulation Thickness |
Sheath Thickness |
Approx. O.D. |
Approx Weight |
Max. D.C. Resistance of Conductor (20°C) |
Test Voltage A.C |
Current Rating |
|
mm2 |
mm |
mm |
mm |
kg/km |
Ω/km |
kV/5min |
In air(A) |
In soil(A) |
4×4 |
0.7 |
1.8 |
13 |
197 |
7.41 |
3.5 |
34 |
45 |
4×6 |
0.7 |
1.8 |
14.2 |
233 |
4.61 |
3.5 |
43 |
57 |
4×10 |
0.7 |
1.8 |
17.2 |
345 |
3.08 |
3.5 |
60 |
77 |
4×16 |
0.7 |
1.8 |
19.9 |
442 |
1.91 |
3.5 |
83 |
105 |
4×25 |
0.9 |
1.8 |
23.4 |
595 |
1.2 |
3.5 |
105 |
125 |
4×35 |
0.9 |
1.8 |
25.8 |
734 |
0.868 |
3.5 |
125 |
155 |
4×50 |
1 |
1.9 |
27.2 |
912 |
0.641 |
3.5 |
160 |
185 |
4×70 |
1.1 |
2 |
27.9 |
1207 |
0.443 |
3.5 |
200 |
225 |
4×95 |
1.1 |
2.1 |
33.8 |
1569 |
0.32 |
3.5 |
245 |
270 |
4×120 |
1.2 |
2.3 |
35.8 |
1923 |
0.253 |
3.5 |
285 |
310 |
4×150 |
1.4 |
2.4 |
40.2 |
2374 |
0.206 |
3.5 |
325 |
345 |
4×185 |
1.6 |
2.6 |
43.6 |
2899 |
0.164 |
3.5 |
375 |
390 |
4×240 |
1.7 |
2.8 |
49.3 |
3670 |
0.125 |
3.5 |
440 |
450 |
4×300 |
1.8 |
3 |
54.1 |
4499 |
0.1 |
3.5 |
505 |
515 |
4×400 |
2 |
3.3 |
65.1 |
5947 |
0.0778 |
3.5 |
570 |
575 |
5 Core Aluminum Power Cable |
||||||||
Nom. Cross-section of conductor |
Insulation Thickness |
Sheath Thickness |
Approx. O.D. |
Approx Weight |
Max. D.C. Resistance of Conductor (20°C) |
Test Voltage A.C |
Current Rating |
|
mm2 |
mm |
mm |
mm |
kg/km |
Ω/km |
kV/5min |
In air(A) |
In soil(A) |
5×4 |
0.7 |
1.8 |
14 |
223 |
7.41 |
3.5 |
34 |
45 |
5×6 |
0.7 |
1.8 |
15.3 |
266 |
4.61 |
3.5 |
43 |
57 |
5×10 |
0.7 |
1.8 |
18.7 |
395 |
3.08 |
3.5 |
60 |
77 |
5×16 |
0.7 |
1.8 |
21.7 |
512 |
1.91 |
3.5 |
83 |
105 |
5×25 |
0.9 |
1.8 |
25.6 |
700 |
1.2 |
3.5 |
105 |
125 |
5×35 |
0.9 |
1.8 |
28.3 |
872 |
0.868 |
3.5 |
125 |
155 |
5×50 |
1 |
2 |
31.6 |
1155 |
0.641 |
3.5 |
160 |
185 |
5×70 |
1.1 |
2.1 |
37.2 |
1536 |
0.443 |
3.5 |
200 |
225 |
5×95 |
1.1 |
2.3 |
41 |
1971 |
0.32 |
3.5 |
245 |
270 |
5×120 |
1.2 |
2.4 |
46.2 |
2430 |
0.253 |
3.5 |
285 |
310 |
5×150 |
1.4 |
2.6 |
50.8 |
3036 |
0.206 |
3.5 |
325 |
345 |
5×185 |
1.6 |
2.8 |
56.6 |
3716 |
0.164 |
3.5 |
375 |
390 |
5×240 |
1.7 |
3 |
62.8 |
4677 |
0.125 |
3.5 |
440 |
450 |
5×300 |
1.8 |
3.2 |
71.4 |
5758 |
0.1 |
3.5 |
505 |
515 |
3+1 Core Aluminum Power Cable |
||||||||
Nom. Cross-section of conductor |
Insulation Thickness |
Sheath Thickness |
Approx. O.D. |
Approx Weight |
Max. D.C. Resistance of Conductor (20°C) |
Test Voltage A.C |
Current Rating |
|
mm2 |
mm |
mm |
mm |
kg/km |
Ω/km |
kV/5min |
In air(A) |
In soil(A) |
3×4 + 1×2.5 |
0.7 |
1.8 |
12.7 |
189 |
7.41 |
3.5 |
34 |
45 |
3×6 + 1×4 |
0.7 |
1.8 |
13.9 |
224 |
4.61 |
3.5 |
43 |
57 |
3×10 + 1×6 |
0.7 |
1.8 |
16.4 |
311 |
3.08 |
3.5 |
60 |
77 |
3×16 + 1×10 |
0.7 |
1.8 |
19.2 |
418 |
1.91 |
3.5 |
83 |
105 |
3×25 + 1×16 |
0.9 |
1.8 |
22.5 |
557 |
1.2 |
3.5 |
105 |
125 |
3×35 + 1×16 |
0.9 |
1.8 |
25 |
667 |
0.868 |
3.5 |
125 |
155 |
3×50 + 1×25 |
1 |
1.8 |
25.5 |
833 |
0.641 |
3.5 |
160 |
185 |
3×70 + 1×35 |
1.1 |
1.9 |
28.9 |
1096 |
0.443 |
3.5 |
200 |
225 |
3×95 + 1×50 |
1.1 |
2.1 |
35.3 |
1448 |
0.32 |
3.5 |
245 |
270 |
3×120 + 1×70 |
1.2 |
2.2 |
37.1 |
1787 |
0.253 |
3.5 |
285 |
310 |
3×150 + 1×70 |
1.4 |
2.3 |
41.7 |
2143 |
0.206 |
3.5 |
325 |
345 |
3×185 + 1×95 |
1.6 |
2.5 |
45.3 |
2629 |
0.164 |
3.5 |
375 |
390 |
3×240 + 1×120 |
1.7 |
2.7 |
51.3 |
3314 |
0.125 |
3.5 |
440 |
450 |
3×300 + 1×150 |
1.8 |
2.9 |
56.3 |
4062 |
0.1 |
3.5 |
505 |
515 |
3×400 + 1×240 |
2 |
3.1 |
67.6 |
5295 |
0.0778 |
3.5 |
570 |
575 |
3+2 Core Aluminum Power Cable |
||||||||
Nom. Cross-section of conductor |
Insulation Thickness |
Sheath Thickness |
Approx. O.D. |
Approx Weight |
Max. D.C. Resistance of Conductor (20°C) |
Test Voltage A.C |
Current Rating |
|
mm2 |
mm |
mm |
mm |
kg/km |
Ω/km |
kV/5min |
In air(A) |
In soil(A) |
3×4 + 2×2.5 |
0.7 |
1.8 |
13.5 |
208 |
7.41 |
3.5 |
34 |
45 |
3×6 + 2×4 |
0.7 |
1.8 |
14.8 |
249 |
4.61 |
3.5 |
43 |
57 |
3×10 + 2×6 |
0.7 |
1.8 |
17.4 |
343 |
3.08 |
3.5 |
60 |
77 |
3×16 + 2×10 |
0.7 |
1.8 |
20.5 |
465 |
1.91 |
3.5 |
83 |
105 |
3×25 + 2×16 |
0.9 |
1.8 |
24 |
625 |
1.2 |
3.5 |
105 |
125 |
3×35 + 2×16 |
0.9 |
1.8 |
25.7 |
728 |
0.868 |
3.5 |
125 |
155 |
3×50 + 2×35 |
1 |
1.9 |
29 |
980 |
0.641 |
3.5 |
160 |
185 |
3×70 + 2×35 |
1.1 |
2 |
33.8 |
1284 |
0.443 |
3.5 |
200 |
225 |
3×95 + 2×50 |
1.1 |
2.2 |
37.4 |
1660 |
0.32 |
3.5 |
245 |
270 |
3×120 + 2×70 |
1.2 |
2.3 |
42.8 |
2089 |
0.253 |
3.5 |
285 |
310 |
3×150 + 2×70 |
1.4 |
2.4 |
45.2 |
2424 |
0.206 |
3.5 |
325 |
345 |
3×185 + 2×95 |
1.6 |
2.6 |
50.6 |
3010 |
0.164 |
3.5 |
375 |
390 |
3×240 + 2×120 |
1.7 |
2.8 |
56 |
3772 |
0.125 |
3.5 |
440 |
450 |
3×300 + 2×150 |
1.8 |
3 |
64.6 |
4673 |
0.1 |
3.5 |
505 |
515 |
4+1 Core Aluminum Power Cable |
||||||||
Nom. Cross-section of conductor |
Insulation Thickness |
Sheath Thickness |
Approx. O.D. |
Approx Weight |
Max. D.C. Resistance of Conductor (20°C) |
Test Voltage A.C |
Current Rating |
|
mm2 |
mm |
mm |
mm |
kg/km |
Ω/km |
kV/5min |
In air(A) |
In soil(A) |
4×6 + 1×4 |
0.7 |
1.8 |
15 |
259 |
4.61 |
3.5 |
43 |
57 |
4×10 + 1×6 |
0.7 |
1.8 |
17.7 |
364 |
3.08 |
3.5 |
60 |
77 |
4×16 + 1×10 |
0.7 |
1.8 |
20.3 |
490 |
1.91 |
3.5 |
83 |
105 |
4×25 + 1×16 |
0.9 |
1.8 |
24.2 |
665 |
1.2 |
3.5 |
105 |
125 |
4×35 + 1×16 |
0.9 |
1.8 |
26.4 |
803 |
0.868 |
3.5 |
125 |
155 |
4×50 + 1×25 |
1 |
1.9 |
32.6 |
1114 |
0.641 |
3.5 |
160 |
185 |
4×70 + 1×35 |
1.1 |
2.1 |
37.4 |
1806 |
0.443 |
3.5 |
200 |
225 |
4×95 + 1×50 |
1.1 |
2.2 |
42.4 |
2211 |
0.32 |
3.5 |
245 |
270 |
4×120 + 1×70 |
1.2 |
2.4 |
47.9 |
2677 |
0.253 |
3.5 |
285 |
310 |
4×150 + 1×70 |
1.4 |
2.5 |
51.9 |
3135 |
0.206 |
3.5 |
325 |
345 |
4×185 + 1×95 |
1.6 |
2.7 |
58 |
4038 |
0.164 |
3.5 |
375 |
390 |
4×240 + 1×120 |
1.7 |
2.9 |
65.1 |
4919 |
0.125 |
3.5 |
440 |
450 |
4×300 + 1×150 |
1.8 |
3.1 |
72 |
5957 |
0.1 |
3.5 |
505 |
515 |
FAQ
Q: Can we have our logo or company name to be printed on your products or the package?
A: The OEM & ODM order is warmly welcome and we have fully successful experience in OEM projects. What's more, our R&D team will give you the professional suggestions.
Q: What’s the payment terms?
A: 30% T/T deposit, 70% T/T balance payment before shipment.
Q: How does your factory do regarding quality control?
A: We have a strict quality control system, and our professional experts will check the appearance and test functions of all our items before shipment.
Q: How can I get a sample to test your quality?
A: We can provide free samples for your test and checking, just need to bear the freight charge.