Steel Wire Armoured SWA Power Cable
Application
Steel wire armoured cable or SWA cable is a hard-wearing cable made up of Black PVC Sheath, xlpe insulation, copper conductors and steel wire armouring. SWA Cable is designed for mains electricity for laying underground, power networks, incoming mains to homes amongst a host of other applications externally and internally.
Constrution
Characteristics
Conductor: Aluminum or Copper
Armoured: SWA(Steel Wire Armoured)
Insulation: XLPE (cross-linked polyethylene) rated at 90°C
Cores: 1, 2, 3, 4, 5, 3+1, 4+1, 3+2
Section Area: 1.5mm2-300mm2
Packaging: Iron Or Wooden Drum
Standards
IEC 60502, BS 7870, GB/T12706
Parameters
2 Core Steel Wire Armored Cable |
||||||||||
Nom. Cross-section of conductor |
Insulation Thickness |
Inner Covering Thickness |
Dia. Of Armor Wire |
Sheath Thickness |
Approx. O.D. |
Approx Weight |
Max. D.C. Resistance of Conductor (20°C) |
Test Voltage A.C |
Current Rating |
|
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/km |
Ω/km |
kV/5min |
In air(A) |
In soil(A) |
2x1.5 |
0.7 |
1 |
0.9 |
1.8 |
15 |
330 |
12.1 |
3.5 |
20 |
27 |
2x2.5 |
0.7 |
1 |
0.9 |
1.8 |
16 |
376 |
7.41 |
3.5 |
26 |
35 |
2x4 |
0.7 |
1 |
0.9 |
1.8 |
17 |
554 |
4.61 |
3.5 |
34 |
45 |
2×6 |
0.7 |
1 |
0.9 |
1.8 |
18.2 |
633 |
3.08 |
3.5 |
43 |
57 |
2×10 |
0.7 |
1 |
1.25 |
1.8 |
21 |
797 |
1.83 |
3.5 |
60 |
77 |
2×16 |
0.7 |
1 |
1.6 |
1.8 |
23.5 |
1124 |
1.15 |
3.5 |
83 |
105 |
2×25 |
0.9 |
1 |
1.6 |
1.8 |
26 |
1417 |
0.727 |
3.5 |
105 |
125 |
2×35 |
0.9 |
1 |
1.6 |
1.8 |
30.5 |
1694 |
0.524 |
3.5 |
125 |
155 |
2×50 |
1 |
1 |
1.6 |
1.8 |
27 |
1787 |
0.387 |
3.5 |
160 |
185 |
2×70 |
1.1 |
1 |
1.6 |
2 |
30 |
2181 |
0.268 |
3.5 |
200 |
225 |
2×95 |
1.1 |
1.2 |
1.6 |
2.1 |
34 |
2768 |
0.193 |
3.5 |
245 |
270 |
2×120 |
1.2 |
1.2 |
2 |
2.2 |
36.5 |
3500 |
0.153 |
3.5 |
285 |
310 |
2×150 |
1.4 |
1.2 |
2 |
2.4 |
42 |
4233 |
0.124 |
3.5 |
325 |
345 |
2x185 |
|
1.2 |
2 |
2.5 |
45 |
4979 |
0.0991 |
3.5 |
375 |
390 |
3 Core Steel Wire Armored Cable |
||||||||||
Nom. Cross-section of conductor |
Insulation Thickness |
Inner Covering Thickness |
Dia. Of Armor Wire |
Sheath Thickness |
Approx. O.D. |
Approx Weight |
Max. D.C. Resistance of Conductor (20°C) |
Test Voltage A.C |
Current Rating |
|
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/km |
Ω/km |
kV/5min |
In air(A) |
In soil(A) |
3x1.5 |
0.7 |
1 |
0.9 |
1.8 |
15.8 |
359 |
12.1 |
3.5 |
20 |
27 |
3x2.5 |
0.7 |
1 |
0.9 |
1.8 |
16.8 |
415 |
7.41 |
3.5 |
26 |
35 |
3×4 |
0.7 |
1 |
0.9 |
1.8 |
18 |
611 |
4.61 |
3.5 |
34 |
45 |
3×6 |
0.7 |
1 |
0.9 |
1.8 |
19 |
718 |
3.08 |
3.5 |
43 |
57 |
3×10 |
0.7 |
1 |
1.25 |
1.8 |
22 |
937 |
1.83 |
3.5 |
60 |
77 |
3×16 |
0.7 |
1 |
1.6 |
1.8 |
24.5 |
1318 |
1.15 |
3.5 |
83 |
105 |
3×25 |
0.9 |
1 |
1.6 |
1.8 |
29.2 |
1707 |
0.727 |
3.5 |
105 |
125 |
3×35 |
0.9 |
1 |
1.6 |
1.8 |
32.5 |
2071 |
0.524 |
3.5 |
125 |
155 |
3×50 |
1 |
1 |
1.6 |
1.9 |
33 |
2405 |
0.387 |
3.5 |
160 |
185 |
3×70 |
1.1 |
1 |
1.6 |
2 |
37 |
3084 |
0.268 |
3.5 |
200 |
225 |
3×95 |
1.1 |
1.2 |
1.6 |
2.1 |
43 |
4126 |
0.193 |
3.5 |
245 |
270 |
3×120 |
1.2 |
1.2 |
2 |
2.3 |
45 |
4901 |
0.153 |
3.5 |
285 |
310 |
3×150 |
1.4 |
1.4 |
2 |
2.4 |
51 |
6365 |
0.124 |
3.5 |
325 |
345 |
3×185 |
1.6 |
1.4 |
2 |
2.6 |
56 |
7555 |
0.0991 |
3.5 |
375 |
390 |
3×240 |
1.7 |
1.4 |
2.5 |
2.8 |
62 |
9284 |
0.0754 |
3.5 |
440 |
450 |
3×300 |
1.8 |
1.6 |
2.5 |
3 |
67 |
11226 |
0.0601 |
3.5 |
505 |
515 |
3×400 |
2 |
1.6 |
2.5 |
3.2 |
74 |
15714 |
0.047 |
3.5 |
570 |
575 |
4 Core Steel Wire Armored Cable |
||||||||||
Nom. Cross-section of conductor |
Insulation Thickness |
Inner Covering Thickness |
Dia. Of Armor Wire |
Sheath Thickness |
Approx. O.D. |
Approx Weight |
Max. D.C. Resistance of Conductor (20°C) |
Test Voltage A.C |
Current Rating |
|
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/km |
Ω/km |
kV/5min |
In air(A) |
In soil(A) |
4×4 |
0.7 |
1 |
0.9 |
1.8 |
18 |
699 |
4.61 |
3.5 |
34 |
45 |
4×6 |
0.7 |
1 |
1.25 |
1.8 |
19 |
820 |
3.08 |
3.5 |
43 |
57 |
4×10 |
0.7 |
1 |
1.25 |
1.8 |
22 |
1233 |
1.83 |
3.5 |
60 |
77 |
4×16 |
0.7 |
1 |
1.6 |
1.8 |
24.5 |
1550 |
1.15 |
3.5 |
83 |
105 |
4×25 |
0.9 |
1 |
1.6 |
1.8 |
29.2 |
2036 |
0.727 |
3.5 |
105 |
125 |
4×35 |
0.9 |
1 |
2 |
1.9 |
32.5 |
2501 |
0.524 |
3.5 |
125 |
155 |
4×50 |
1 |
1 |
2 |
2 |
33 |
3064 |
0.387 |
3.5 |
160 |
185 |
4×70 |
1.1 |
1 |
2 |
2.1 |
37 |
3974 |
0.268 |
3.5 |
200 |
225 |
4×95 |
1.1 |
1.2 |
2 |
2.3 |
43 |
5032 |
0.193 |
3.5 |
245 |
270 |
4×120 |
1.2 |
1.2 |
2.5 |
2.4 |
45 |
6327 |
0.153 |
3.5 |
285 |
310 |
4×150 |
1.4 |
1.4 |
2.5 |
2.5 |
51 |
7765 |
0.124 |
3.5 |
325 |
345 |
4×185 |
1.6 |
1.4 |
2.5 |
2.7 |
56 |
9205 |
0.0991 |
3.5 |
375 |
390 |
4×240 |
1.7 |
1.4 |
2.5 |
3 |
62 |
11444 |
0.0754 |
3.5 |
440 |
450 |
4×300 |
1.8 |
1.6 |
2.5 |
3.2 |
67 |
13830 |
0.0601 |
3.5 |
505 |
515 |
4×400 |
2 |
1.6 |
3.15 |
3.5 |
74 |
19673 |
0.047 |
3.5 |
570 |
575 |
FAQ
Q: Can we have our logo or company name to be printed on your products or the package?
A: The OEM & ODM order is warmly welcome and we have fully successful experience in OEM projects. What's more, our R&D team will give you the professional suggestions.
Q: What’s the payment terms?
A: 30% T/T deposit, 70% T/T balance payment before shipment.
Q: How does your factory do regarding quality control?
A: We have a strict quality control system, and our professional experts will check the appearance and test functions of all our items before shipment.
Q: How can I get a sample to test your quality?
A: We can provide free samples for your test and checking, just need to bear the freight charge.