100% Original Factory Rubber Insulation Cable 1×70 mm2 H07RN-F Cable with Copper Conductor
We know that we only thrive if we can easily guarantee our combined price competiveness and excellent advantageous at the same time for 100% Original Factory Rubber Insulation Cable 1×70 mm2 H07RN-F Cable with Copper Conductor, Our hugely specialized process eliminates the component failure and offers our customers unvarying high quality, allowing us to control cost, plan capacity and maintain consistent on time delivery.
We know that we only thrive if we can easily guarantee our combined price competiveness and excellent advantageous at the same time for China Rubber Cable and Rubber Insulated Cable, We give good quality but unbeatable low price and the best service. Welcome to post your samples and color ring to us .We are going to produce the goods according to your request. If you are interested in any items we offer you, you should feel free to contact us directly by mail, fax, telephone or internet. We’ve been here to answer your questions from Monday to Saturday and looking forward to cooperating with you.
Application
These cables are designed to provide high flexibility and have the capacity to withstand weather, oil/grease, mechanical and thermal stresses. Applications include handling equipment, mobile power supplies, worksites, stage and audio visual equipment, port areas and dams. The cables are used in drainage and water treatment, cold environments and severe industrial environments. Also used as electrical connect line or wiring in power installation, household appliances, electrically operated tools, instruction lighting and machines inner rated voltage A.C 450/750V or below.
Constrution
Characteristics
Rated voltage(U0/U) | 450/750V |
Insulation material | Rubber compound |
Sheath material | Rubber compound(CPE) |
Permissible continuous working temperature |
Not exceed 60°C |
Test voltage | 2500 volts |
Flexing bending radius | 6 x Ø |
Fixed bending radius | 4.0 x Ø |
Flexing Temperature | 25ºC to +60ºC |
Fixed Temperature | 40ºC to +60ºC |
Short circuit temperature | +200ºC |
Insulation resistance | 20 MΩ x km |
Cross sectional area | 1.5mm2- 400mm2 |
Cores | 1core; 2 core; 3core; 4core; 5core; 3+1core |
Parameters
1 Core H07rn-f Rubber Cable |
||||||||
Size |
Nominal Insulation Thickness |
Minimum Insulation Thickness |
Nominal Jacket Thickness |
Minimum Jacket Thickness |
Nominal Overall Diameter ±8% |
Approx. Cable Weight |
Nominal Current ar air temp. 30°C |
|
mm2 |
mm |
mm |
mm |
mm |
mm |
KG/KM |
Mobile |
Fixed |
1×1.5 |
0.8 |
0.7 |
1.4 |
1.1 |
5.8 |
52 |
16.5 |
23 |
1×2.5 |
0.9 |
0.7 |
1.4 |
1.1 |
6.3 |
66 |
22 |
32 |
1×4 |
1 |
0.7 |
1.5 |
1.2 |
7.2 |
89 |
30 |
43 |
1×6 |
1 |
0.7 |
1.6 |
1.3 |
7.9 |
113 |
38 |
56 |
1×10 |
1.2 |
1 |
1.8 |
1.4 |
9.5 |
170 |
53 |
77 |
1×16 |
1.2 |
1 |
1.9 |
1.5 |
10.6 |
229 |
71 |
102 |
1×25 |
1.4 |
1.2 |
2 |
1.6 |
12.4 |
327 |
94 |
136 |
1×35 |
1.4 |
1.2 |
2.2 |
1.8 |
13.8 |
422 |
117 |
168 |
1×50 |
1.6 |
1.3 |
2.4 |
1.9 |
16 |
583 |
148 |
203 |
1×70 |
1.6 |
1.3 |
2.6 |
2.1 |
17.8 |
763 |
185 |
254 |
1×95 |
1.8 |
1.5 |
2.8 |
2.3 |
20.2 |
1003 |
222 |
299 |
1×120 |
1.8 |
1.5 |
3 |
2.5 |
22.1 |
1222 |
260 |
363 |
1×150 |
2 |
1.7 |
3.2 |
2.6 |
24.3 |
1497 |
300 |
416 |
1×185 |
2.2 |
1.9 |
3.4 |
2.8 |
26.6 |
1822 |
341 |
475 |
1×240 |
2.4 |
2.1 |
3.5 |
2.9 |
29.4 |
2298 |
407 |
559 |
1×300 |
2.6 |
2.2 |
3.6 |
3 |
32.2 |
2816 |
468 |
637 |
1×400 |
2.8 |
2.4 |
3.8 |
3.1 |
35.9 |
3615 |
468 |
637 |
2 Core H07rn-f Rubber Cable |
||||||||
Size |
Nominal Insulation Thickness |
Minimum Insulation Thickness |
Nominal Jacket Thickness |
Minimum Jacket Thickness |
Nominal Overall Diameter ±8% |
Approx. Cable Weight |
Nominal Current ar air temp. 30°C |
|
mm2 |
mm |
mm |
mm |
mm |
mm |
KG/KM |
Mobile |
Fixed |
2×1.0 |
0.8 |
0.6 |
1.3 |
1 |
8 |
96 |
10 |
18 |
2×1.5 |
0.8 |
0.6 |
1.5 |
1.2 |
8.9 |
122 |
16 |
23 |
2×2.5 |
0.9 |
0.7 |
1.7 |
1.3 |
10.5 |
172 |
25 |
32 |
2×4 |
1.0 |
0.8 |
1.8 |
1.4 |
12 |
233 |
34 |
43 |
2×6 |
1.0 |
0.8 |
2.0 |
1.6 |
13.4 |
299 |
43 |
56 |
2×10 |
1.2 |
1.0 |
3.1 |
2.5 |
18.2 |
538 |
60 |
77 |
2×16 |
1.2 |
1.0 |
3.3 |
2.7 |
20.4 |
709 |
79 |
102 |
2×25 |
1.4 |
1.2 |
3.6 |
3.0 |
24.3 |
1021 |
105 |
136 |
2×35 |
1.4 |
1.2 |
3.8 |
3.1 |
26.7 |
1275 |
130 |
168 |
2×50 |
1.6 |
1.3 |
4.2 |
3.5 |
31.1 |
1758 |
160 |
203 |
2×70 |
1.6 |
1.3 |
4.6 |
3.8 |
34.7 |
2269 |
196 |
254 |
2×95 |
1.8 |
1.5 |
5.0 |
4.2 |
39.5 |
2978 |
238 |
299 |
3 Core H07rn-f Rubber Cable |
||||||||
Size |
Nominal Insulation Thickness |
Minimum Insulation Thickness |
Nominal Jacket Thickness |
Minimum Jacket Thickness |
Nominal Overall Diameter ±8% |
Approx. Cable Weight |
Nominal Current ar air temp. 30°C |
|
mm2 |
mm |
mm |
mm |
mm |
mm |
KG/KM |
Mobile |
Fixed |
3×1.0 |
0.8 |
0.6 |
1.4 |
1.1 |
8.6 |
115 |
10 |
18 |
3×1.5 |
0.8 |
0.6 |
1.6 |
1.3 |
9.6 |
146 |
16 |
23 |
3×2.5 |
0.9 |
0.7 |
1.8 |
1.4 |
11.2 |
206 |
25 |
32 |
3×4 |
1.0 |
0.8 |
1.9 |
1.5 |
12.8 |
282 |
35 |
43 |
3×6 |
1.0 |
0.8 |
2.1 |
1.7 |
14.3 |
363 |
44 |
56 |
3×10 |
1.2 |
1.0 |
3.3 |
2.7 |
19.5 |
654 |
60 |
77 |
3×16 |
1.2 |
1.0 |
3.5 |
2.9 |
21.9 |
870 |
82 |
102 |
3×25 |
1.4 |
1.2 |
3.8 |
3.1 |
26.0 |
1257 |
109 |
136 |
3×35 |
1.4 |
1.2 |
4.1 |
3.4 |
28.8 |
1593 |
135 |
168 |
3×50 |
1.6 |
1.3 |
4.5 |
3.7 |
33.4 |
2198 |
169 |
203 |
3×70 |
1.6 |
1.3 |
4.8 |
4.0 |
37.1 |
2832 |
211 |
254 |
3×95 |
1.8 |
1.5 |
5.3 |
4.4 |
42.4 |
3747 |
250 |
299 |
3×120 |
1.8 |
1.5 |
5.6 |
4.7 |
46.2 |
4528 |
290 |
263 |
3×150 |
2.0 |
1.7 |
6.0 |
5.0 |
50.9 |
5549 |
332 |
416 |
4 Core H07rn-f Rubber Cable |
||||||||
Size |
Nominal Insulation Thickness |
Minimum Insulation Thickness |
Nominal Jacket Thickness |
Minimum Jacket Thickness |
Nominal Overall Diameter ±8% |
Approx. Cable Weight |
Nominal Current ar air temp. 30°C |
|
mm2 |
mm |
mm |
mm |
mm |
mm |
KG/KM |
Mobile |
Fixed |
4×1.0 |
0.8 |
0.6 |
1.5 |
1.2 |
9.5 |
141 |
10 |
16 |
4×1.5 |
0.8 |
0.6 |
1.7 |
1.3 |
10.5 |
179 |
16 |
21 |
4×2.5 |
0.9 |
0.7 |
1.9 |
1.5 |
12.3 |
253 |
20 |
29 |
4×4 |
1.0 |
0.8 |
2 |
1.6 |
14.1 |
348 |
30 |
38 |
4×6 |
1.0 |
0.8 |
2.3 |
1.9 |
15.9 |
457 |
37 |
50 |
4×10 |
1.2 |
1.0 |
3.4 |
2.8 |
21.2 |
797 |
52 |
68 |
4×16 |
1.2 |
1.0 |
3.6 |
3.0 |
23.8 |
1068 |
69 |
92 |
4×25 |
1.4 |
1.2 |
4.1 |
3.4 |
28.8 |
1580 |
92 |
122 |
4×35 |
1.4 |
1.2 |
4.4 |
3.6 |
31.8 |
2004 |
114 |
150 |
4×50 |
1.6 |
1.3 |
4.8 |
4.0 |
36.9 |
2766 |
143 |
282 |
4×70 |
1.6 |
1.3 |
5.2 |
4.3 |
41.1 |
3592 |
178 |
232 |
4×95 |
1.8 |
1.5 |
5.9 |
4.9 |
47.3 |
4799 |
210 |
281 |
4×120 |
1.8 |
1.5 |
6.0 |
5.0 |
51.2 |
5739 |
246 |
325 |
4×150 |
2.0 |
1.7 |
6.5 |
5.4 |
56.5 |
7060 |
280 |
373 |
4×185 |
2.2 |
1.9 |
7 |
5.9 |
62.1 |
8613 |
330 |
424 |
4×240 |
2.4 | 2.1 | 7.7 | 6.4 | 69.8 | 11025 | 408 | 480 |
5 Core H07rn-f Rubber Cable |
||||||||
Size |
Nominal Insulation Thickness |
Minimum Insulation Thickness |
Nominal Jacket Thickness |
Minimum Jacket Thickness |
Nominal Overall Diameter ±8% |
Approx. Cable Weight |
Nominal Current ar air temp. 30°C |
|
mm2 |
mm |
mm |
mm |
mm |
mm |
KG/KM |
Mobile |
Fixed |
5×1.0 |
0.8 |
0.6 |
1.6 |
1.3 |
10.5 |
173 |
10 |
16 |
5×1.5 |
0.8 |
0.6 |
1.8 |
1.4 |
11.6 |
218 |
16 |
21 |
5×2.5 |
0.9 |
0.7 |
2.0 |
1.6 |
13.5 |
308 |
20 |
29 |
5×4 |
1.0 |
0.8 |
2.2 |
1.8 |
15.7 |
432 |
30 |
38 |
5×6 |
1.0 |
0.8 |
2.5 |
2.0 |
17.6 |
566 |
38 |
50 |
5×10 |
1.2 |
1.0 |
3.6 |
3.0 |
23.3 |
970 |
54 |
68 |
5×16 |
1.2 |
1.0 |
3.9 |
3.2 |
26.4 |
1316 |
71 |
92 |
5×25 |
1.4 |
1.2 |
4.4 |
3.6 |
31.8 |
1943 |
94 |
122 |
5×35 |
1.4 |
1.2 |
4.6 |
3.8 |
34.9 |
2444 |
114 |
150 |
5×50 |
1.6 |
1.3 |
5.2 |
4.3 |
40.9 |
3420 |
143 |
182 |
5×70 |
1.6 |
1.3 |
5.7 |
4.7 |
45.7 |
4462 |
178 |
232 |
5×95 |
1.8 |
1.5 |
6.3 |
5.3 |
52.3 |
5914 |
210 |
281 |
5×120 |
1.8 |
1.5 |
6.3 |
5.3 |
56.4 |
7050 |
246 |
325 |
5×150 |
2.0 |
1.7 |
6.8 |
5.7 |
62.2 |
8668 |
280 |
373 |
We know that we only thrive if we can easily guarantee our combined price competiveness and excellent advantageous at the same time for 100% Original Factory Rubber Insulation Cable 1×70 mm2 H07RN-F Cable with Copper Conductor, Our hugely specialized process eliminates the component failure and offers our customers unvarying high quality, allowing us to control cost, plan capacity and maintain consistent on time delivery.
100% Original Factory China Rubber Cable and Rubber Insulated Cable, We give good quality but unbeatable low price and the best service. Welcome to post your samples and color ring to us .We are going to produce the goods according to your request. If you are interested in any items we offer you, you should feel free to contact us directly by mail, fax, telephone or internet. We’ve been here to answer your questions from Monday to Saturday and looking forward to cooperating with you.