2019 China New Design 0.6/1kv Yjv Yjv22 23 XLPE Cable PVC Insulated Armoured Flexible Power Cable

Short Description:

The cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.

 

 

Acceptance: OEM/ODM, Trade, Wholesale, Regional Agency

Payment: T/T, L/C, PayPal

Stock Sample is Free & Available


Product Detail

Product Tags

Together with the “Client-Oriented” company philosophy, a rigorous high-quality regulate program, sophisticated producing gear and a solid R&D staff, we constantly deliver premium quality solutions, superb products and services and aggressive price ranges for 2019 China New Design 0.6/1kv Yjv Yjv22 23 XLPE Cable PVC Insulated Armoured Flexible Power Cable, Accurate process devices, Advanced Injection Molding Equipment, Equipment assembly line, labs and software advancement are our distinguishing feature.
Together with the “Client-Oriented” company philosophy, a rigorous high-quality regulate program, sophisticated producing gear and a solid R&D staff, we constantly deliver premium quality solutions, superb products and services and aggressive price ranges for China 0.6/1kv and Yjv Yjv22 23, If you will need any of our merchandise, or have other items to be produced, remember to send us your inquiries, samples or comprehensive drawings. Meanwhile, aiming to develop into an international enterprise group, we look forward to receiving offers for joint ventures and other cooperative projects.

Application

Indoors cable trunking, outdoors for power stations, industry and switchgear as well as for urban supply networks, if mechanical damage is unlikely

Constrution

avava

Characteristics

Rated voltage: 0.6/1kV

1.during normal operation of cable, the maximum conductor temperature shall be 70℃ for PVC insulation and 90℃ for XLPE insulation.
2.Maximum temperature of conductor during short circuit (maximum duration not exceeding 5 seconds) : PVC insulation — 160℃ for conductor cross section ≤300mm2, 140℃ for conductor cross section > 300mm2;  Crosslinked PVC insulation at 250℃.
3.When laying cables, the ambient temperature shall not be less than 0℃, and the minimum allowable bending radius is as follows:
Single core cable: unarmored 20D, armored 15D
Multi-core cable: 15D for unarmored, 12D for armored
Where: D- actual outer diameter of cable.
4.Cable breaking force:
Aluminum core cable: 40×S (N)
Copper core cable: 70×S (N)
Note: S is the total cross-sectional area of the conductor

Standards

IEC 60502-1, GB/T 12706.1

Parameters

Single Core Power Cable

Nom. Cross-section of conductor

Insulation Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

1×1.5

0.7

1.4

6

53

12.1

3.5

22

33

1×2.5

0.7

1.4

6

68

7.41

3.5

31

43

1×4

0.7

1.4

7

87

4.61

3.5

41

56

1×6

0.7

1.4

7

110

3.08

3.5

52

70

1×10

0.7

1.4

8

155

1.83

3.5

71

94

1×16

0.7

1.4

9

220

1.15

3.5

92

120

1×25

0.9

1.4

10

345

0.727

3.5

120

155

1×35

0.9

1.4

12

424

0.524

3.5

150

185

1×50

1

1.4

13

555

0.387

3.5

180

220

1×70

1.1

1.4

14

770

0.268

3.5

230

270

1×95

1.1

1.5

16

1040

0.193

3.5

285

320

1×120

1.2

1.5

18

1290

0.153

3.5

335

365

1×150

1.4

1.6

20

1590

0.124

3.5

385

410

1×185

1.6

1.6

22

1944

0.0991

3.5

450

465

1×240

1.7

1.7

25

2510

0.0754

3.5

535

540

1×300

1.8

1.8

27

3042

0.0601

3.5

620

610

1×400

2

1.9

31

3869

0.047

3.5

720

695

1×500

2.2

2.1

35

4910

0.0366

3.5

835

780

1×630

2.4

2.2

40

6220

0.0283

3.5

960

880

1×800

2.6

2.4

45

7870

0.0221

3.5

1110

970

1×1000

2.8

2.6

51

9804

0.0176

3.5

1230

1060

2 Core Power Cable

Nom. Cross-section of conductor

Insulation Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

2×2.5

0.7

1.8

11.8

151

7.41

3.5

26

35

2×4

0.7

1.8

12.7

198

4.61

3.5

34

45

2×6

0.7

1.8

13.7

250

3.08

3.5

43

57

2×10

0.7

1.8

15

374

1.83

3.5

60

77

2×16

0.7

1.8

17

518

1.15

3.5

83

105

2×25

0.9

1.8

20

772

0.727

3.5

105

125

2×35

0.9

1.8

22

1006

0.524

3.5

125

155

2×50

1

1.8

20

1365

0.387

3.5

160

185

2×70

1.1

1.8

21

1872

0.268

3.5

200

225

2×95

1.1

1.8

24

2475

0.193

3.5

245

270

2×120

1.2

1.8

27

3089

0.153

3.5

285

310

2×150

1.4

1.9

30

3834

0.124

3.5

325

345

3 Core Power Cable

Nom. Cross-section of conductor

Insulation Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

3×1.5

0.7

1.5

10

145

12.1

3.5

20

27

3×2.5

0.7

1.5

11

185

7.41

3.5

26

35

3×4

0.7

1.5

12

250

4.61

3.5

34

45

3×6

0.7

1.5

13

320

3.08

3.5

43

57

3×10

0.7

1.8

16

450

1.83

3.5

60

77

3×16

0.7

1.8

18

640

1.15

3.5

83

105

3×25

0.9

1.8

21

940

0.727

3.5

105

125

3×35

0.9

1.8

23

1260

0.524

3.5

125

155

3×50

1

1.8

23

1670

0.387

3.5

160

185

3×70

1.1

1.8

26

2280

0.268

3.5

200

225

3×95

1.1

1.9

30

3020

0.193

3.5

245

270

3×120

1.2

2

32

3790

0.153

3.5

285

310

3×150

1.4

2.2

37

4750

0.124

3.5

325

345

3×185

1.6

2.3

41

5654

0.0991

3.5

375

390

3×240

1.7

2.4

46

7243

0.0754

3.5

440

450

3×300

1.8

2.6

51

9465

0.0601

3.5

505

515

3×400

2

3

64

12066

0.047

3.5

570

575

4 Core Power Cable

Nom. Cross-section of conductor

Insulation Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

4×4

0.7

1.8

13

253

4.61

3.5

34

45

4×6

0.7

1.8

14

337

3.08

3.5

43

57

4×10

0.7

1.8

17

501

1.83

3.5

60

77

4×16

0.7

1.8

20

778

1.15

3.5

83

105

4×25

0.9

1.8

23

1160

0.727

3.5

105

125

4×35

0.9

1.8

25

1554

0.524

3.5

125

155

4×50

1

1.8

23

2148

0.387

3.5

160

185

4×70

1.1

1.8

27

2928

0.268

3.5

200

225

4×95

1.1

1.9

31

3854

0.193

3.5

245

270

4×120

1.2

2

33

4925

0.153

3.5

285

310

4×150

1.4

2.2

38

6238

0.124

3.5

325

345

4×185

1.6

2.3

42

7562

0.0991

3.5

375

390

4×240

1.7

2.5

47

9836

0.0754

3.5

440

450

4×300

1.8

2.6

52

12550

0.0601

3.5

505

515

4×400

2

3.1

66

15929

0.047

3.5

570

575

5 Core Power Cable

Nom. Cross-section of conductor

Insulation Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

5×4

0.7

1.8

14.5

349

4.61

3.5

34

45

5×6

0.7

1.8

15.8

460

3.08

3.5

43

57

5×10

0.7

1.8

19

699

1.83

3.5

60

77

5×16

0.7

1.8

22

1013

1.15

3.5

83

105

5×25

0.9

1.8

25

1566

0.727

3.5

105

125

5×35

0.9

1.9

28

2083

0.524

3.5

125

155

5×50

1

2

31

2921

0.387

3.5

160

185

5×70

1.1

2.1

36

3974

0.268

3.5

200

225

5×95

1.1

2.2

39

5297

0.193

3.5

245

270

5×120

1.2

2.4

44

6638

0.153

3.5

285

310

5×150

1.4

2.5

49

8290

0.124

3.5

325

345

5×185

1.6

2.7

55

10215

0.0991

3.5

375

390

5×240

1.7

3

64

13130

0.0754

3.5

440

450

5×300

1.8

3.2

70

16670

0.0601

3.5

505

515

3+1 Core Power Cable

Nom. Cross-section of conductor

Insulation Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

3×4+1×2.5

0.7

1.8

13

236

4.61

3.5

34

45

3×6+1×4

0.7

1.8

14

316

3.08

3.5

43

57

3×10+1×6

0.7

1.8

17

461

1.83

3.5

60

77

3×16+1×10

0.7

1.8

19

679

1.15

3.5

83

105

3×25+1×16

0.9

1.8

22

1065

0.727

3.5

105

125

3×35+1×16

0.9

1.8

24

1360

0.524

3.5

125

155

3×50+1×25

1

1.8

25

1901

0.387

3.5

160

185

3×70+1×35

1.1

1.9

28

2585

0.268

3.5

200

225

3×95+1×50

1.1

2

32

3518

0.193

3.5

245

270

3×120+1×70

1.2

2.1

35

4443

0.153

3.5

285

310

3×150+1×70

1.4

2.2

40

5326

0.124

3.5

325

345

3×185+1×95

1.6

2.4

43

8501

0.0991

3.5

375

390

3×240+1×120

1.7

2.5

48

11155

0.0754

3.5

440

450

3×300+1×150

1.8

2.7

54

14470

0.0601

3.5

505

515

3×400+1×240

2

3.1

66

309

0.047

3.5

570

575

3+2 Core Power Cable

Nom. Cross-section of conductor

Insulation Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

3×4+2×2.5

0.7

1.8

13.9

413

4.61

3.5

34

45

3×6+2×4

0.7

1.8

15.3

6682

3.08

3.5

43

57

3×10+2×6

0.7

1.8

18

603

1.83

3.5

60

77

3×16+2×10

0.7

1.8

21

888

1.15

3.5

83

105

3×25+2×16

0.9

1.8

24

1342

0.727

3.5

105

125

3×35+2×16

0.9

1.8

26

1647

0.524

3.5

125

155

3×50+2×35

1

1.9

29

2386

0.387

3.5

160

185

3×70+2×35

1.1

2

32

3201

0.268

3.5

200

225

3×95+2×50

1.1

2.1

36

4269

0.193

3.5

245

270

3×120+2×70

1.2

2.3

41

5437

0.153

3.5

285

310

3×150+2×70

1.4

2.4

44

6519

0.124

3.5

325

345

3×185+2×95

1.6

2.5

49

8101

0.0991

3.5

375

390

3×240+2×120

1.7

2.7

54

10340

0.0754

3.5

440

450

3×300+2×150

1.8

2.8

56

12810

0.0601

3.5

505

515

4+1 Core Power Cable

Nom. Cross-section of conductor

Insulation Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

4×4+1×2.5

0.7

1.8

14.5

331

4.61

3.5

34

45

4×6+1×4

0.7

1.8

15.9

435

3.08

3.5

43

57

4×10+1×6

0.7

1.8

18

649

1.83

3.5

60

77

4×16+1×10

0.7

1.8

21

965

1.15

3.5

83

105

4×25+1×16

0.9

1.8

25

1456

0.727

3.5

105

125

4×35+1×16

0.9

1.8

27

1863

0.524

3.5

125

155

4×50+1×25

1

1.9

29

2633

0.387

3.5

160

185

4×70+1×35

1.1

2

32

3565

0.268

3.5

200

225

4×95+1×50

1.1

2.1

36

4735

0.193

3.5

245

270

4×120+1×70

1.2

2.3

41

5977

0.153

3.5

285

310

4×150+1×70

1.4

2.4

44

7276

0.124

3.5

325

345

4×185+1×95

1.6

2.5

49

9055

0.0991

3.5

375

390

4×240+1×120

1.7

2.7

54

11567

0.0754

3.5

440

450

4×300+1×150

1.8

3.1

66

14321

0.0601

3.5

505

515

包装与运输Together with the “Client-Oriented” company philosophy, a rigorous high-quality regulate program, sophisticated producing gear and a solid R&D staff, we constantly deliver premium quality solutions, superb products and services and aggressive price ranges for 2019 China New Design 0.6/1kv Yjv Yjv22 23 XLPE Cable PVC Insulated Armoured Flexible Power Cable, Accurate process devices, Advanced Injection Molding Equipment, Equipment assembly line, labs and software advancement are our distinguishing feature.
2019 China New Design China 0.6/1kv and Yjv Yjv22 23, If you will need any of our merchandise, or have other items to be produced, remember to send us your inquiries, samples or comprehensive drawings. Meanwhile, aiming to develop into an international enterprise group, we look forward to receiving offers for joint ventures and other cooperative projects.


  • Previous:
  • Next:

  • Write your message here and send it to us