We are proud in the significant client satisfaction and wide acceptance due to our persistent pursuit of top quality both on merchandise and repair for Best quality 4 Core 50mm Swa PVC Electricity Steel Tape Armoured Cable, Top quality, timely company and Aggressive cost, all win us a superior fame in xxx field despite the international intense competition.
We are proud in the significant client satisfaction and wide acceptance due to our persistent pursuit of top quality both on merchandise and repair for China Wire Cable and Cable Wire, Our products are widely sold to Europe, USA, Russia, UK, France, Australia, Middle East, South America, Africa, and Southeast Asia, etc. Our solutions are highly recognized by our customers from all around the world. And our company is committed to continually improving effectiveness of our management system to maximize customer satisfaction. We sincerely hope to make progress with our customers and create a win-win future together. Welcome to join us for business!

Application

Xlpe insulated pvc sheathed steel tape armoured Cable is composed of pure copper conductor, XLPE insulation, steel tape armor, and flame-retardant PVC sheath. Multicore industrial cables are suitable for 0.6/1KV rated voltage, able to withstand certain mechanical gravity, which can be used for power stations, subway, tunnels, high-rise buildings, large industrial and mining enterprises, oil fields, coal mines, and other places of intensive distributed electric cables.

Constrution

AVAVBA

Characteristics

Rated voltage: 0.6 / 1 kV

Maximum Conductor Temperature: under normal (90℃), emergency (130℃) or short circuit no more than 5 s (250℃) conditions.
Min. Ambient Temp. 0℃, after installation and only when cable is in a fixed position
Min. Bending Radius: 12 x cable O.D for multi core

Standards

IEC 60502-1, GB/T 12706.1

Application

transmission and distribution lines with 50 Hz AC rated voltage Uo/U of 0.6/1KV and below shall be transported; Suitable for buried laying, not suitable for laying in pipelines.

Parameters

2 Core Steel Tape Armoured Cable

Nom. Cross-section of conductor

Insulation Thickness

Inner Covering Thickness

Steel Tape Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

2×4

0.7

1.2

2×0.2

1.8

15

433

4.61

3.5

34

45

2×6

0.7

1.2

2×0.2

1.8

16

500

3.08

3.5

43

57

2×10

0.7

1.2

2×0.2

1.8

19

673

1.83

3.5

60

77

2×16

0.7

1.4

2×0.2

1.8

21

857

1.15

3.5

83

105

2×25

0.9

1.4

2×0.2

1.8

24

1173

0.727

3.5

105

125

2×35

0.9

1.6

2×0.2

1.8

25

1449

0.524

3.5

125

155

2×50

1

1.6

2×0.2

1.8

26

1877

0.387

3.5

160

185

2×70

1.1

1.8

2×0.2

1.8

27

2454

0.268

3.5

200

225

2×95

1.1

1.8

2×0.2

1.9

30

2483

0.193

3.5

245

270

2×120

1.2

2

2×0.2

2

33

4213

0.153

3.5

285

310

2×150

1.4

2

2×0.5

2.2

38

5087

0.124

3.5

325

345

3 Core Steel Tape Armoured Cable

Nom. Cross-section of conductor

Insulation Thickness

Inner Covering Thickness

Steel Tape Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

3×1.5

0.7

1

2×0.2

1.5

13

273

12.1

3.5

20

27

3×2.5

0.7

1

2×0.2

1.5

14

321

7.41

3.5

26

35

3×4

0.7

1.2

2×0.2

1.5

15

390

4.61

3.5

34

45

3×6

0.7

1.2

2×0.2

1.5

16

471

3.08

3.5

43

57

3×10

0.7

1.4

2×0.2

1.5

18

622

1.83

3.5

60

77

3×16

0.7

1.4

2×0.2

2

22

1005

1.15

3.5

83

105

3×25

0.9

1.6

2×0.2

2

25

1371

0.727

3.5

105

125

3×35

0.9

1.6

2×0.2

2

27

1724

0.524

3.5

125

155

3×50

1

1.8

2×0.2

2

30

2247

0.387

3.5

160

185

3×70

1.1

1.8

2×0.2

2.5

35

3023

0.268

3.5

200

225

3×95

1.1

2

2×0.5

2.5

39

3825

0.193

3.5

245

270

3×120

1.2

2

2×0.5

2.5

42

4642

0.153

3.5

285

310

3×150

1.4

2

2×0.5

3

48

5767

0.124

3.5

325

345

3×185

1.6

2.2

2×0.5

3

51

6895

0.0991

3.5

375

390

3×240

1.7

2.2

2×0.5

3

56

8617

0.0754

3.5

440

450

3×300

1.8

2.2

2×0.5

3

59

10928

0.0601

3.5

505

515

3×400

2

2.2

2×0.5

3.2

61

13556

0.047

3.5

570

575

4 Core Steel Tape Armoured Cable

Nom. Cross-section of conductor

Insulation Thickness

Inner Covering Thickness

Steel Tape Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

4×4

0.7

1

2×0.2

1.5

16

454

4.61

3.5

34

45

4×6

0.7

1

2×0.2

1.5

17

557

3.08

3.5

43

57

4×10

0.7

1

2×0.2

2

20

791

1.83

3.5

60

77

4×16

0.7

1

2×0.2

2

23

1210

1.15

3.5

83

105

4×25

0.9

1

2×0.2

2

27

1672

0.727

3.5

105

125

4×35

0.9

1

2×0.2

2

29

2127

0.524

3.5

125

155

4×50

1

1

2×0.2

2

33

2802

0.387

3.5

160

185

4×70

1.1

1.2

2×0.2

2.5

38

3785

0.268

3.5

200

225

4×95

1.1

1.2

2×0.5

2.5

42

4829

0.193

3.5

245

270

4×120

1.2

1.4

2×0.5

3

47

6033

0.153

3.5

285

310

4×150

1.4

1.4

2×0.5

3

52

7356

0.124

3.5

325

345

4×185

1.6

1.6

2×0.5

3

56

8806

0.0991

3.5

375

390

4×240

1.7

1.6

2×0.5

3

62

11182

0.0754

3.5

440

450

4×300

1.8

1.7

2×0.5

3.1

64

14176

0.0601

3.5

505

515

4×400

2

1.7

2×0.5

3.5

69

17815

0.047

3.5

570

575

5 Core Steel Tape Armoured Cable

Nom. Cross-section of conductor

Insulation Thickness

Inner Covering Thickness

Steel Tape Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

5×4

0.7

1

2×0.2

1.5

17.1

588

4.61

3.5

34

45

5×6

0.7

1

2×0.2

1.5

19.4

720

3.08

3.5

43

57

5×10

0.7

1

2×0.2

2

22.9

1014

1.83

3.5

60

77

5×16

0.7

1

2×0.2

2

25.8

1392

1.15

3.5

83

105

5×25

0.9

1

2×0.2

2

30.5

2002

0.727

3.5

105

125

5×35

0.9

1

2×0.2

2

33.7

2581

0.524

3.5

125

155

5×50

1

1

2×0.5

2

38.6

3722

0.387

3.5

160

185

5×70

1.1

1.2

2×0.5

2.5

43.4

4897

0.268

3.5

200

225

5×95

1.1

1.2

2×0.5

2.5

48.6

6338

0.193

3.5

245

270

5×120

1.2

1.4

2×0.5

3

54.4

7851

0.153

3.5

285

310

5×150

1.4

1.4

2×0.5

3

60.1

9661

0.124

3.5

325

345

5×185

1.6

1.6

2×0.5

3

66.7

11770

0.0991

3.5

375

390

5×240

1.7

1.6

2×0.5

3

74.7

14900

0.0754

3.5

440

450

5×300

1.8

1.7

2×0.5

3.1

83.2

18000

0.0601

3.5

505

515

3+1 Core Steel Tape Armoured Cable

Nom. Cross-section of conductor

Insulation Thickness

Inner Covering Thickness

Steel Tape Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

3×4 + 1×2.5

0.7

1

2×0.2

1.5

16

443

4.61

3.5

34

45

3×6 + 1×4

0.7

1

2×0.2

1.5

17

531

3.08

3.5

43

57

3×10 + 1×6

0.7

1

2×0.2

2

20

741

1.83

3.5

60

77

3×16 + 1×10

0.7

1

2×0.2

2

23

1135

1.15

3.5

83

105

3×25 + 1×16

0.9

1

2×0.2

2

26

1556

0.727

3.5

105

125

3×35 + 1×16

0.9

1

2×0.2

2

28

1896

0.524

3.5

125

155

3×50 + 1×25

1

1

2×0.2

2

31

2518

0.387

3.5

160

185

3×70 + 1×35

1.1

1.2

2×0.2

2.5

36

3293

0.268

3.5

200

225

3×95 + 1×50

1.1

1.2

2×0.5

2.5

40

4349

0.193

3.5

245

270

3×120 + 1×70

1.2

1.2

2×0.5

2.5

44

5365

0.153

3.5

285

310

3×150 + 1×70

1.4

1.4

2×0.5

3

49

6468

0.124

3.5

325

345

3×185 + 1×95

1.6

1.4

2×0.5

3

52

7854

0.0991

3.5

375

390

3×240 + 1×120

1.7

1.6

2×0.5

3.5

68

9814

0.0754

3.5

440

450

3×300 + 1×150

1.8

1.7

2×0.5

3.5

71

12781

0.0601

3.5

505

515

3×400 + 1×240

2

1.7

2×0.5

3.5

76

16359

0.047

3.5

570

575

3+2 Core Steel Tape Armoured Cable

Nom. Cross-section of conductor

Insulation Thickness

Inner Covering Thickness

Steel Tape Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

3×4 + 2×2.5

0.7

1

2×0.2

1.5

17.5

855

4.61

3.5

34

45

3×6 + 2×4

0.7

1

2×0.2

1.5

18.9

1009

3.08

3.5

43

57

3×10 + 2×6

0.7

1

2×0.2

2

21.6

1461

1.83

3.5

60

77

3×16 + 2×10

0.7

1

2×0.2

2

24.6

1877

1.15

3.5

83

105

3×25 + 2×16

0.9

1

2×0.2

2

28.7

2583

0.727

3.5

105

125

3×35 + 2×16

0.9

1

2×0.2

2

30.7

3001

0.524

3.5

125

155

3×50 + 2×35

1

1

2×0.2

2

36.2

4392

0.387

3.5

160

185

3×70 + 2×35

1.1

1.2

2×0.2

2.5

40.3

5519

0.268

3.5

200

225

3×95 + 2×50

1.1

1.2

2×0.5

2.5

44.9

7543

0.193

3.5

245

270

3×120 + 2×70

1.2

1.2

2×0.5

2.5

50.3

9203

0.153

3.5

285

310

3×150 + 2×70

1.4

1.4

2×0.5

3

54

10485

0.124

3.5

325

345

3×185 + 2×95

1.6

1.4

2×0.5

3

60.2

13945

0.0991

3.5

375

390

3×240 + 2×120

1.7

1.6

2×0.5

3.5

67.2

15643

0.0754

3.5

440

450

3×300 + 2×150

1.8

1.7

2×0.5

3.5

75.2

18204

0.0601

3.5

505

515

4+1 Core Steel Tape Armoured Cable

Nom. Cross-section of conductor

Insulation Thickness

Inner Covering Thickness

Steel Tape Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

4×4 + 1×2.5

0.7

1

2×0.2

1.5

18.4

565

4.61

3.5

34

45

4×6 + 1×4

0.7

1

2×0.2

1.5

19.8

692

3.08

3.5

43

57

4×10 + 1×6

0.7

1

2×0.2

2

22.8

953

1.83

3.5

60

77

4×16 + 1×10

0.7

1

2×0.2

2

25.8

1318

1.15

3.5

83

105

4×25 + 1×16

0.9

1

2×0.2

2

30.4

1877

0.727

3.5

105

125

4×35 + 1×16

0.9

1

2×0.2

2

34.1

2324

0.524

3.5

125

155

4×50 + 1×25

1

1

2×0.2

2

38.7

3415

0.387

3.5

160

185

4×70 + 1×35

1.1

1.2

2×0.5

2.5

44.2

4432

0.268

3.5

200

225

4×95 + 1×50

1.1

1.2

2×0.5

2.5

49.8

5747

0.193

3.5

245

270

4×120 + 1×70

1.2

1.2

2×0.5

2.5

55.4

7112

0.153

3.5

285

310

4×150 + 1×70

1.4

1.4

2×0.5

3

60.1

8556

0.124

3.5

325

345

4×185 + 1×95

1.6

1.4

2×0.5

3

66.9

10510

0.0991

3.5

375

390

4×240 + 1×120

1.7

1.6

2×0.5

3.5

74.8

13232

0.0754

3.5

440

450

4×300 + 1×150

1.8

1.7

2×0.5

3.5

78.4

16452

0.0601

3.5

505

515

We are proud in the significant client satisfaction and wide acceptance due to our persistent pursuit of top quality both on merchandise and repair for Best quality 4 Core 50mm Swa PVC Electricity Steel Tape Armoured Cable, Top quality, timely company and Aggressive cost, all win us a superior fame in xxx field despite the international intense competition.
Best quality China Wire Cable and Cable Wire, Our products are widely sold to Europe, USA, Russia, UK, France, Australia, Middle East, South America, Africa, and Southeast Asia, etc. Our solutions are highly recognized by our customers from all around the world. And our company is committed to continually improving effectiveness of our management system to maximize customer satisfaction. We sincerely hope to make progress with our customers and create a win-win future together. Welcome to join us for business!


  • Previous:
  • Next:

  • Write your message here and send it to us