China Cheap price Low Voltage Multicore XLPE Insualted Unarmoured Power Cable with Ce Certificate

Short Description:

The cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.

 

 

Acceptance: OEM/ODM, Trade, Wholesale, Regional Agency

Payment: T/T, L/C, PayPal

Stock Sample is Free & Available


Product Detail

Product Tags

Our solutions are widely recognized and trusted by consumers and will meet up with constantly developing financial and social requires for China Cheap price Low Voltage Multicore XLPE Insualted Unarmoured Power Cable with Ce Certificate, We wish to just take this opportunity to ascertain long-term enterprise relationships with clients from all over the earth.
Our solutions are widely recognized and trusted by consumers and will meet up with constantly developing financial and social requires for China Unarmoured Cable and Low Voltage Power Cable, We welcome you to visit our company and factory. It is also convenient to visit our website. Our sales team will offer you the best service. If you need to have more information, you should feel free to contact us by E-mail or telephone. We have been sincerely hope to establish a good long-term business relationship with you through this opportunity, based on equal, mutual benefit from now till the future.

Application

Indoors cable trunking, outdoors for power stations, industry and switchgear as well as for urban supply networks, if mechanical damage is unlikely

Constrution

avava

Characteristics

Rated voltage: 0.6/1kV

1.during normal operation of cable, the maximum conductor temperature shall be 70℃ for PVC insulation and 90℃ for XLPE insulation.
2.Maximum temperature of conductor during short circuit (maximum duration not exceeding 5 seconds) : PVC insulation — 160℃ for conductor cross section ≤300mm2, 140℃ for conductor cross section > 300mm2;  Crosslinked PVC insulation at 250℃.
3.When laying cables, the ambient temperature shall not be less than 0℃, and the minimum allowable bending radius is as follows:
Single core cable: unarmored 20D, armored 15D
Multi-core cable: 15D for unarmored, 12D for armored
Where: D- actual outer diameter of cable.
4.Cable breaking force:
Aluminum core cable: 40×S (N)
Copper core cable: 70×S (N)
Note: S is the total cross-sectional area of the conductor

Standards

IEC 60502-1, GB/T 12706.1

Parameters

Single Core Power Cable

Nom. Cross-section of conductor

Insulation Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

1×1.5

0.7

1.4

6

53

12.1

3.5

22

33

1×2.5

0.7

1.4

6

68

7.41

3.5

31

43

1×4

0.7

1.4

7

87

4.61

3.5

41

56

1×6

0.7

1.4

7

110

3.08

3.5

52

70

1×10

0.7

1.4

8

155

1.83

3.5

71

94

1×16

0.7

1.4

9

220

1.15

3.5

92

120

1×25

0.9

1.4

10

345

0.727

3.5

120

155

1×35

0.9

1.4

12

424

0.524

3.5

150

185

1×50

1

1.4

13

555

0.387

3.5

180

220

1×70

1.1

1.4

14

770

0.268

3.5

230

270

1×95

1.1

1.5

16

1040

0.193

3.5

285

320

1×120

1.2

1.5

18

1290

0.153

3.5

335

365

1×150

1.4

1.6

20

1590

0.124

3.5

385

410

1×185

1.6

1.6

22

1944

0.0991

3.5

450

465

1×240

1.7

1.7

25

2510

0.0754

3.5

535

540

1×300

1.8

1.8

27

3042

0.0601

3.5

620

610

1×400

2

1.9

31

3869

0.047

3.5

720

695

1×500

2.2

2.1

35

4910

0.0366

3.5

835

780

1×630

2.4

2.2

40

6220

0.0283

3.5

960

880

1×800

2.6

2.4

45

7870

0.0221

3.5

1110

970

1×1000

2.8

2.6

51

9804

0.0176

3.5

1230

1060

2 Core Power Cable

Nom. Cross-section of conductor

Insulation Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

2×2.5

0.7

1.8

11.8

151

7.41

3.5

26

35

2×4

0.7

1.8

12.7

198

4.61

3.5

34

45

2×6

0.7

1.8

13.7

250

3.08

3.5

43

57

2×10

0.7

1.8

15

374

1.83

3.5

60

77

2×16

0.7

1.8

17

518

1.15

3.5

83

105

2×25

0.9

1.8

20

772

0.727

3.5

105

125

2×35

0.9

1.8

22

1006

0.524

3.5

125

155

2×50

1

1.8

20

1365

0.387

3.5

160

185

2×70

1.1

1.8

21

1872

0.268

3.5

200

225

2×95

1.1

1.8

24

2475

0.193

3.5

245

270

2×120

1.2

1.8

27

3089

0.153

3.5

285

310

2×150

1.4

1.9

30

3834

0.124

3.5

325

345

3 Core Power Cable

Nom. Cross-section of conductor

Insulation Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

3×1.5

0.7

1.5

10

145

12.1

3.5

20

27

3×2.5

0.7

1.5

11

185

7.41

3.5

26

35

3×4

0.7

1.5

12

250

4.61

3.5

34

45

3×6

0.7

1.5

13

320

3.08

3.5

43

57

3×10

0.7

1.8

16

450

1.83

3.5

60

77

3×16

0.7

1.8

18

640

1.15

3.5

83

105

3×25

0.9

1.8

21

940

0.727

3.5

105

125

3×35

0.9

1.8

23

1260

0.524

3.5

125

155

3×50

1

1.8

23

1670

0.387

3.5

160

185

3×70

1.1

1.8

26

2280

0.268

3.5

200

225

3×95

1.1

1.9

30

3020

0.193

3.5

245

270

3×120

1.2

2

32

3790

0.153

3.5

285

310

3×150

1.4

2.2

37

4750

0.124

3.5

325

345

3×185

1.6

2.3

41

5654

0.0991

3.5

375

390

3×240

1.7

2.4

46

7243

0.0754

3.5

440

450

3×300

1.8

2.6

51

9465

0.0601

3.5

505

515

3×400

2

3

64

12066

0.047

3.5

570

575

4 Core Power Cable

Nom. Cross-section of conductor

Insulation Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

4×4

0.7

1.8

13

253

4.61

3.5

34

45

4×6

0.7

1.8

14

337

3.08

3.5

43

57

4×10

0.7

1.8

17

501

1.83

3.5

60

77

4×16

0.7

1.8

20

778

1.15

3.5

83

105

4×25

0.9

1.8

23

1160

0.727

3.5

105

125

4×35

0.9

1.8

25

1554

0.524

3.5

125

155

4×50

1

1.8

23

2148

0.387

3.5

160

185

4×70

1.1

1.8

27

2928

0.268

3.5

200

225

4×95

1.1

1.9

31

3854

0.193

3.5

245

270

4×120

1.2

2

33

4925

0.153

3.5

285

310

4×150

1.4

2.2

38

6238

0.124

3.5

325

345

4×185

1.6

2.3

42

7562

0.0991

3.5

375

390

4×240

1.7

2.5

47

9836

0.0754

3.5

440

450

4×300

1.8

2.6

52

12550

0.0601

3.5

505

515

4×400

2

3.1

66

15929

0.047

3.5

570

575

5 Core Power Cable

Nom. Cross-section of conductor

Insulation Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

5×4

0.7

1.8

14.5

349

4.61

3.5

34

45

5×6

0.7

1.8

15.8

460

3.08

3.5

43

57

5×10

0.7

1.8

19

699

1.83

3.5

60

77

5×16

0.7

1.8

22

1013

1.15

3.5

83

105

5×25

0.9

1.8

25

1566

0.727

3.5

105

125

5×35

0.9

1.9

28

2083

0.524

3.5

125

155

5×50

1

2

31

2921

0.387

3.5

160

185

5×70

1.1

2.1

36

3974

0.268

3.5

200

225

5×95

1.1

2.2

39

5297

0.193

3.5

245

270

5×120

1.2

2.4

44

6638

0.153

3.5

285

310

5×150

1.4

2.5

49

8290

0.124

3.5

325

345

5×185

1.6

2.7

55

10215

0.0991

3.5

375

390

5×240

1.7

3

64

13130

0.0754

3.5

440

450

5×300

1.8

3.2

70

16670

0.0601

3.5

505

515

3+1 Core Power Cable

Nom. Cross-section of conductor

Insulation Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

3×4+1×2.5

0.7

1.8

13

236

4.61

3.5

34

45

3×6+1×4

0.7

1.8

14

316

3.08

3.5

43

57

3×10+1×6

0.7

1.8

17

461

1.83

3.5

60

77

3×16+1×10

0.7

1.8

19

679

1.15

3.5

83

105

3×25+1×16

0.9

1.8

22

1065

0.727

3.5

105

125

3×35+1×16

0.9

1.8

24

1360

0.524

3.5

125

155

3×50+1×25

1

1.8

25

1901

0.387

3.5

160

185

3×70+1×35

1.1

1.9

28

2585

0.268

3.5

200

225

3×95+1×50

1.1

2

32

3518

0.193

3.5

245

270

3×120+1×70

1.2

2.1

35

4443

0.153

3.5

285

310

3×150+1×70

1.4

2.2

40

5326

0.124

3.5

325

345

3×185+1×95

1.6

2.4

43

8501

0.0991

3.5

375

390

3×240+1×120

1.7

2.5

48

11155

0.0754

3.5

440

450

3×300+1×150

1.8

2.7

54

14470

0.0601

3.5

505

515

3×400+1×240

2

3.1

66

309

0.047

3.5

570

575

3+2 Core Power Cable

Nom. Cross-section of conductor

Insulation Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

3×4+2×2.5

0.7

1.8

13.9

413

4.61

3.5

34

45

3×6+2×4

0.7

1.8

15.3

6682

3.08

3.5

43

57

3×10+2×6

0.7

1.8

18

603

1.83

3.5

60

77

3×16+2×10

0.7

1.8

21

888

1.15

3.5

83

105

3×25+2×16

0.9

1.8

24

1342

0.727

3.5

105

125

3×35+2×16

0.9

1.8

26

1647

0.524

3.5

125

155

3×50+2×35

1

1.9

29

2386

0.387

3.5

160

185

3×70+2×35

1.1

2

32

3201

0.268

3.5

200

225

3×95+2×50

1.1

2.1

36

4269

0.193

3.5

245

270

3×120+2×70

1.2

2.3

41

5437

0.153

3.5

285

310

3×150+2×70

1.4

2.4

44

6519

0.124

3.5

325

345

3×185+2×95

1.6

2.5

49

8101

0.0991

3.5

375

390

3×240+2×120

1.7

2.7

54

10340

0.0754

3.5

440

450

3×300+2×150

1.8

2.8

56

12810

0.0601

3.5

505

515

4+1 Core Power Cable

Nom. Cross-section of conductor

Insulation Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

4×4+1×2.5

0.7

1.8

14.5

331

4.61

3.5

34

45

4×6+1×4

0.7

1.8

15.9

435

3.08

3.5

43

57

4×10+1×6

0.7

1.8

18

649

1.83

3.5

60

77

4×16+1×10

0.7

1.8

21

965

1.15

3.5

83

105

4×25+1×16

0.9

1.8

25

1456

0.727

3.5

105

125

4×35+1×16

0.9

1.8

27

1863

0.524

3.5

125

155

4×50+1×25

1

1.9

29

2633

0.387

3.5

160

185

4×70+1×35

1.1

2

32

3565

0.268

3.5

200

225

4×95+1×50

1.1

2.1

36

4735

0.193

3.5

245

270

4×120+1×70

1.2

2.3

41

5977

0.153

3.5

285

310

4×150+1×70

1.4

2.4

44

7276

0.124

3.5

325

345

4×185+1×95

1.6

2.5

49

9055

0.0991

3.5

375

390

4×240+1×120

1.7

2.7

54

11567

0.0754

3.5

440

450

4×300+1×150

1.8

3.1

66

14321

0.0601

3.5

505

515

包装与运输Our solutions are widely recognized and trusted by consumers and will meet up with constantly developing financial and social requires for China Cheap price Low Voltage Multicore XLPE Insualted Unarmoured Power Cable with Ce Certificate, We wish to just take this opportunity to ascertain long-term enterprise relationships with clients from all over the earth.
China Cheap price China Unarmoured Cable and Low Voltage Power Cable, We welcome you to visit our company and factory. It is also convenient to visit our website. Our sales team will offer you the best service. If you need to have more information, you should feel free to contact us by E-mail or telephone. We have been sincerely hope to establish a good long-term business relationship with you through this opportunity, based on equal, mutual benefit from now till the future.


  • Previous:
  • Next:

  • Write your message here and send it to us