Factory supplied 0.6/1kv Aluminum Conductor Copper Conductor Electrical Power Cable

Short Description:

The 0.6/1kv Xlpe insulated Pvc sheathed aluminum power cable are used for power distribution in power stations, industrial installation and switchgears, as well as in local mains. Able to bear certain traction during installation. For fixed installation underground.

 

 

Acceptance: OEM/ODM, Trade, Wholesale, Regional Agency

Payment: T/T, L/C, PayPal


Product Detail

Product Tags

Our intention would be to fulfill our consumers by offering golden support, great price and high-quality for Factory supplied 0.6/1kv Aluminum Conductor Copper Conductor Electrical Power Cable, “Quality”, “honesty” and “service” is our principle. Our loyalty and commitments remain respectfully at your service. Speak to Us Today For even further data, make contact with us now.
Our intention would be to fulfill our consumers by offering golden support, great price and high-quality for China Electric Cable and Electrical Cable, The development of our company not only needs the guarantee of quality, reasonable price and perfect service, but also relies on our customer’s trust and support! In the future, we’ll continue with the most experienced and high quality service to supply the most competitive price, Together with our customers and achieve win-win! Welcome to inquiry and consult!

Application

Used in Indoors, in tunnel or cable trench, non-armoured cables unable to bear external mechanical forces.

Constrution

AVAV

Characteristics

Rated voltage  0.6/1kV
Conductor  Aluminum
Insulation  XLPE
Sheath  PVC
Core  1, 2, 3, 4, 5, 3+1, 3+2, 4+1
Color  Black or Customized

Standards

GB/T 12706、IEC、BS、DIN and ICEA upon request

Parameters

2 Core Aluminum Power Cable

Nom. Cross-section of conductor

Insulation Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

2×4

0.7

1.8

11.4

150

7.41

3.5

34

45

2×6

0.7

1.8

12.4

171

4.61

3.5

43

57

2×10

0.7

1.8

14.9

238

3.08

3.5

60

77

2×16

0.7

1.8

17.1

294

1.91

3.5

83

105

2×25

0.9

1.8

20

394

1.2

3.5

105

125

2×35

0.9

1.8

22

484

0.868

3.5

125

155

2×50

1

1.8

23.4

497

0.641

3.5

160

185

2×70

1.1

1.8

24.5

640

0.443

3.5

200

225

2×95

1.1

1.9

28.6

827

0.32

3.5

245

270

2×120

1.2

2

29.7

1015

0.253

3.5

285

310

2×150

1.4

2.2

31.2

1268

0.206

3.5

325

345

3 Core Aluminum Power Cable

Nom. Cross-section of conductor

Insulation Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

3×4

0.7

1.8

12

163

7.41

3.5

34

45

3×6

0.7

1.8

13

191

4.61

3.5

43

57

3×10

0.7

1.8

15.8

282

3.08

3.5

60

77

3×16

0.7

1.8

18.2

358

1.91

3.5

83

105

3×25

0.9

1.8

21.3

491

1.2

3.5

105

125

3×35

0.9

1.8

23.6

600

0.868

3.5

125

155

3×50

1

1.8

23.8

729

0.641

3.5

160

185

3×70

1.1

1.9

27.4

958

0.443

3.5

200

225

3×95

1.1

2

33.1

1242

0.32

3.5

245

270

3×120

1.2

2.1

34.7

1502

0.253

3.5

285

310

3×150

1.4

2.3

39.1

1875

0.206

3.5

325

345

3×185

1.6

2.4

42.3

2264

0.164

3.5

375

390

3×240

1.7

2.6

47.8

2861

0.125

3.5

440

450

3×300

1.8

2.8

52.4

3501

0.1

3.5

505

515

3×400

2

3.1

62.9

4627

0.0778

3.5

570

575

4 Core Aluminum Power Cable

Nom. Cross-section of conductor

Insulation Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

4×4

0.7

1.8

13

197

7.41

3.5

34

45

4×6

0.7

1.8

14.2

233

4.61

3.5

43

57

4×10

0.7

1.8

17.2

345

3.08

3.5

60

77

4×16

0.7

1.8

19.9

442

1.91

3.5

83

105

4×25

0.9

1.8

23.4

595

1.2

3.5

105

125

4×35

0.9

1.8

25.8

734

0.868

3.5

125

155

4×50

1

1.9

27.2

912

0.641

3.5

160

185

4×70

1.1

2

27.9

1207

0.443

3.5

200

225

4×95

1.1

2.1

33.8

1569

0.32

3.5

245

270

4×120

1.2

2.3

35.8

1923

0.253

3.5

285

310

4×150

1.4

2.4

40.2

2374

0.206

3.5

325

345

4×185

1.6

2.6

43.6

2899

0.164

3.5

375

390

4×240

1.7

2.8

49.3

3670

0.125

3.5

440

450

4×300

1.8

3

54.1

4499

0.1

3.5

505

515

4×400

2

3.3

65.1

5947

0.0778

3.5

570

575

5 Core Aluminum Power Cable

Nom. Cross-section of conductor

Insulation Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

5×4

0.7

1.8

14

223

7.41

3.5

34

45

5×6

0.7

1.8

15.3

266

4.61

3.5

43

57

5×10

0.7

1.8

18.7

395

3.08

3.5

60

77

5×16

0.7

1.8

21.7

512

1.91

3.5

83

105

5×25

0.9

1.8

25.6

700

1.2

3.5

105

125

5×35

0.9

1.8

28.3

872

0.868

3.5

125

155

5×50

1

2

31.6

1155

0.641

3.5

160

185

5×70

1.1

2.1

37.2

1536

0.443

3.5

200

225

5×95

1.1

2.3

41

1971

0.32

3.5

245

270

5×120

1.2

2.4

46.2

2430

0.253

3.5

285

310

5×150

1.4

2.6

50.8

3036

0.206

3.5

325

345

5×185

1.6

2.8

56.6

3716

0.164

3.5

375

390

5×240

1.7

3

62.8

4677

0.125

3.5

440

450

5×300

1.8

3.2

71.4

5758

0.1

3.5

505

515

3+1 Core Aluminum Power Cable

Nom. Cross-section of conductor

Insulation Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

3×4 + 1×2.5

0.7

1.8

12.7

189

7.41

3.5

34

45

3×6 + 1×4

0.7

1.8

13.9

224

4.61

3.5

43

57

3×10 + 1×6

0.7

1.8

16.4

311

3.08

3.5

60

77

3×16 + 1×10

0.7

1.8

19.2

418

1.91

3.5

83

105

3×25 + 1×16

0.9

1.8

22.5

557

1.2

3.5

105

125

3×35 + 1×16

0.9

1.8

25

667

0.868

3.5

125

155

3×50 + 1×25

1

1.8

25.5

833

0.641

3.5

160

185

3×70 + 1×35

1.1

1.9

28.9

1096

0.443

3.5

200

225

3×95 + 1×50

1.1

2.1

35.3

1448

0.32

3.5

245

270

3×120 + 1×70

1.2

2.2

37.1

1787

0.253

3.5

285

310

3×150 + 1×70

1.4

2.3

41.7

2143

0.206

3.5

325

345

3×185 + 1×95

1.6

2.5

45.3

2629

0.164

3.5

375

390

3×240 + 1×120

1.7

2.7

51.3

3314

0.125

3.5

440

450

3×300 + 1×150

1.8

2.9

56.3

4062

0.1

3.5

505

515

3×400 + 1×240

2

3.1

67.6

5295

0.0778

3.5

570

575

3+2 Core Aluminum Power Cable

Nom. Cross-section of conductor

Insulation Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

3×4 + 2×2.5

0.7

1.8

13.5

208

7.41

3.5

34

45

3×6 + 2×4

0.7

1.8

14.8

249

4.61

3.5

43

57

3×10 + 2×6

0.7

1.8

17.4

343

3.08

3.5

60

77

3×16 + 2×10

0.7

1.8

20.5

465

1.91

3.5

83

105

3×25 + 2×16

0.9

1.8

24

625

1.2

3.5

105

125

3×35 + 2×16

0.9

1.8

25.7

728

0.868

3.5

125

155

3×50 + 2×35

1

1.9

29

980

0.641

3.5

160

185

3×70 + 2×35

1.1

2

33.8

1284

0.443

3.5

200

225

3×95 + 2×50

1.1

2.2

37.4

1660

0.32

3.5

245

270

3×120 + 2×70

1.2

2.3

42.8

2089

0.253

3.5

285

310

3×150 + 2×70

1.4

2.4

45.2

2424

0.206

3.5

325

345

3×185 + 2×95

1.6

2.6

50.6

3010

0.164

3.5

375

390

3×240 + 2×120

1.7

2.8

56

3772

0.125

3.5

440

450

3×300 + 2×150

1.8

3

64.6

4673

0.1

3.5

505

515

4+1 Core Aluminum Power Cable

Nom. Cross-section of conductor

Insulation Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

4×6 + 1×4

0.7

1.8

15

259

4.61

3.5

43

57

4×10 + 1×6

0.7

1.8

17.7

364

3.08

3.5

60

77

4×16 + 1×10

0.7

1.8

20.3

490

1.91

3.5

83

105

4×25 + 1×16

0.9

1.8

24.2

665

1.2

3.5

105

125

4×35 + 1×16

0.9

1.8

26.4

803

0.868

3.5

125

155

4×50 + 1×25

1

1.9

32.6

1114

0.641

3.5

160

185

4×70 + 1×35

1.1

2.1

37.4

1806

0.443

3.5

200

225

4×95 + 1×50

1.1

2.2

42.4

2211

0.32

3.5

245

270

4×120 + 1×70

1.2

2.4

47.9

2677

0.253

3.5

285

310

4×150 + 1×70

1.4

2.5

51.9

3135

0.206

3.5

325

345

4×185 + 1×95

1.6

2.7

58

4038

0.164

3.5

375

390

4×240 + 1×120

1.7

2.9

65.1

4919

0.125

3.5

440

450

4×300 + 1×150

1.8

3.1

72

5957

0.1

3.5

505

515

Our intention would be to fulfill our consumers by offering golden support, great price and high-quality for Factory supplied 0.6/1kv Aluminum Conductor Copper Conductor Electrical Power Cable, “Quality”, “honesty” and “service” is our principle. Our loyalty and commitments remain respectfully at your service. Speak to Us Today For even further data, make contact with us now.
Factory supplied China Electric Cable and Electrical Cable, The development of our company not only needs the guarantee of quality, reasonable price and perfect service, but also relies on our customer’s trust and support! In the future, we’ll continue with the most experienced and high quality service to supply the most competitive price, Together with our customers and achieve win-win! Welcome to inquiry and consult!