Factory wholesale 3 Core 4 Core 5 Core 16mm 25mm 35mm 95mm Aluminum/Copper Core Steel Wire PVC/XLPE Underground Power Armoured Cable

Short Description:

The cable are mainly used for power distribution in power stations, industrial installation and switch gears, as well as in local mains. Apply to shafts, water and soil, able to bear the larger positive pressure.

 

 

Acceptance: OEM/ODM, Trade, Wholesale, Regional Agency

Payment: T/T, L/C, PayPal

Stock Sample is Free & Available


Product Detail

Product Tags

We emphasize advancement and introduce new products into the market each year for Factory wholesale 3 Core 4 Core 5 Core 16mm 25mm 35mm 95mm Aluminum/Copper Core Steel Wire PVC/XLPE Underground Power Armoured Cable, How about to start your good enterprise with our corporation? We’re ready, qualified and fulfilled with pride. Let’s start our new organization with new wave.
We emphasize advancement and introduce new products into the market each year for China Copper Wire and Wire, To create more creative goods, maintain high-quality products and solutions and update not only our goods but ourselves so as to keep us ahead of the world, and the last but most vital one: to make every client satisfied with everything we offer you and to grow stronger together. To be the real winner, starts here!

Application

Xlpe insulated pvc sheathed steel tape armoured Cable is composed of pure copper conductor, XLPE insulation, steel tape armor, and flame-retardant PVC sheath. Multicore industrial cables are suitable for 0.6/1KV rated voltage, able to withstand certain mechanical gravity, which can be used for power stations, subway, tunnels, high-rise buildings, large industrial and mining enterprises, oil fields, coal mines, and other places of intensive distributed electric cables.

Constrution

AVAVBA

Characteristics

Rated voltage: 0.6 / 1 kV

Maximum Conductor Temperature: under normal (90℃), emergency (130℃) or short circuit no more than 5 s (250℃) conditions.
Min. Ambient Temp. 0℃, after installation and only when cable is in a fixed position
Min. Bending Radius: 12 x cable O.D for multi core

Standards

IEC 60502-1, GB/T 12706.1

Application

transmission and distribution lines with 50 Hz AC rated voltage Uo/U of 0.6/1KV and below shall be transported; Suitable for buried laying, not suitable for laying in pipelines.

Parameters

2 Core Steel Tape Armoured Cable

Nom. Cross-section of conductor

Insulation Thickness

Inner Covering Thickness

Steel Tape Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

2×4

0.7

1.2

2×0.2

1.8

15

433

4.61

3.5

34

45

2×6

0.7

1.2

2×0.2

1.8

16

500

3.08

3.5

43

57

2×10

0.7

1.2

2×0.2

1.8

19

673

1.83

3.5

60

77

2×16

0.7

1.4

2×0.2

1.8

21

857

1.15

3.5

83

105

2×25

0.9

1.4

2×0.2

1.8

24

1173

0.727

3.5

105

125

2×35

0.9

1.6

2×0.2

1.8

25

1449

0.524

3.5

125

155

2×50

1

1.6

2×0.2

1.8

26

1877

0.387

3.5

160

185

2×70

1.1

1.8

2×0.2

1.8

27

2454

0.268

3.5

200

225

2×95

1.1

1.8

2×0.2

1.9

30

2483

0.193

3.5

245

270

2×120

1.2

2

2×0.2

2

33

4213

0.153

3.5

285

310

2×150

1.4

2

2×0.5

2.2

38

5087

0.124

3.5

325

345

3 Core Steel Tape Armoured Cable

Nom. Cross-section of conductor

Insulation Thickness

Inner Covering Thickness

Steel Tape Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

3×1.5

0.7

1

2×0.2

1.5

13

273

12.1

3.5

20

27

3×2.5

0.7

1

2×0.2

1.5

14

321

7.41

3.5

26

35

3×4

0.7

1.2

2×0.2

1.5

15

390

4.61

3.5

34

45

3×6

0.7

1.2

2×0.2

1.5

16

471

3.08

3.5

43

57

3×10

0.7

1.4

2×0.2

1.5

18

622

1.83

3.5

60

77

3×16

0.7

1.4

2×0.2

2

22

1005

1.15

3.5

83

105

3×25

0.9

1.6

2×0.2

2

25

1371

0.727

3.5

105

125

3×35

0.9

1.6

2×0.2

2

27

1724

0.524

3.5

125

155

3×50

1

1.8

2×0.2

2

30

2247

0.387

3.5

160

185

3×70

1.1

1.8

2×0.2

2.5

35

3023

0.268

3.5

200

225

3×95

1.1

2

2×0.5

2.5

39

3825

0.193

3.5

245

270

3×120

1.2

2

2×0.5

2.5

42

4642

0.153

3.5

285

310

3×150

1.4

2

2×0.5

3

48

5767

0.124

3.5

325

345

3×185

1.6

2.2

2×0.5

3

51

6895

0.0991

3.5

375

390

3×240

1.7

2.2

2×0.5

3

56

8617

0.0754

3.5

440

450

3×300

1.8

2.2

2×0.5

3

59

10928

0.0601

3.5

505

515

3×400

2

2.2

2×0.5

3.2

61

13556

0.047

3.5

570

575

4 Core Steel Tape Armoured Cable

Nom. Cross-section of conductor

Insulation Thickness

Inner Covering Thickness

Steel Tape Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

4×4

0.7

1

2×0.2

1.5

16

454

4.61

3.5

34

45

4×6

0.7

1

2×0.2

1.5

17

557

3.08

3.5

43

57

4×10

0.7

1

2×0.2

2

20

791

1.83

3.5

60

77

4×16

0.7

1

2×0.2

2

23

1210

1.15

3.5

83

105

4×25

0.9

1

2×0.2

2

27

1672

0.727

3.5

105

125

4×35

0.9

1

2×0.2

2

29

2127

0.524

3.5

125

155

4×50

1

1

2×0.2

2

33

2802

0.387

3.5

160

185

4×70

1.1

1.2

2×0.2

2.5

38

3785

0.268

3.5

200

225

4×95

1.1

1.2

2×0.5

2.5

42

4829

0.193

3.5

245

270

4×120

1.2

1.4

2×0.5

3

47

6033

0.153

3.5

285

310

4×150

1.4

1.4

2×0.5

3

52

7356

0.124

3.5

325

345

4×185

1.6

1.6

2×0.5

3

56

8806

0.0991

3.5

375

390

4×240

1.7

1.6

2×0.5

3

62

11182

0.0754

3.5

440

450

4×300

1.8

1.7

2×0.5

3.1

64

14176

0.0601

3.5

505

515

4×400

2

1.7

2×0.5

3.5

69

17815

0.047

3.5

570

575

5 Core Steel Tape Armoured Cable

Nom. Cross-section of conductor

Insulation Thickness

Inner Covering Thickness

Steel Tape Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

5×4

0.7

1

2×0.2

1.5

17.1

588

4.61

3.5

34

45

5×6

0.7

1

2×0.2

1.5

19.4

720

3.08

3.5

43

57

5×10

0.7

1

2×0.2

2

22.9

1014

1.83

3.5

60

77

5×16

0.7

1

2×0.2

2

25.8

1392

1.15

3.5

83

105

5×25

0.9

1

2×0.2

2

30.5

2002

0.727

3.5

105

125

5×35

0.9

1

2×0.2

2

33.7

2581

0.524

3.5

125

155

5×50

1

1

2×0.5

2

38.6

3722

0.387

3.5

160

185

5×70

1.1

1.2

2×0.5

2.5

43.4

4897

0.268

3.5

200

225

5×95

1.1

1.2

2×0.5

2.5

48.6

6338

0.193

3.5

245

270

5×120

1.2

1.4

2×0.5

3

54.4

7851

0.153

3.5

285

310

5×150

1.4

1.4

2×0.5

3

60.1

9661

0.124

3.5

325

345

5×185

1.6

1.6

2×0.5

3

66.7

11770

0.0991

3.5

375

390

5×240

1.7

1.6

2×0.5

3

74.7

14900

0.0754

3.5

440

450

5×300

1.8

1.7

2×0.5

3.1

83.2

18000

0.0601

3.5

505

515

3+1 Core Steel Tape Armoured Cable

Nom. Cross-section of conductor

Insulation Thickness

Inner Covering Thickness

Steel Tape Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

3×4 + 1×2.5

0.7

1

2×0.2

1.5

16

443

4.61

3.5

34

45

3×6 + 1×4

0.7

1

2×0.2

1.5

17

531

3.08

3.5

43

57

3×10 + 1×6

0.7

1

2×0.2

2

20

741

1.83

3.5

60

77

3×16 + 1×10

0.7

1

2×0.2

2

23

1135

1.15

3.5

83

105

3×25 + 1×16

0.9

1

2×0.2

2

26

1556

0.727

3.5

105

125

3×35 + 1×16

0.9

1

2×0.2

2

28

1896

0.524

3.5

125

155

3×50 + 1×25

1

1

2×0.2

2

31

2518

0.387

3.5

160

185

3×70 + 1×35

1.1

1.2

2×0.2

2.5

36

3293

0.268

3.5

200

225

3×95 + 1×50

1.1

1.2

2×0.5

2.5

40

4349

0.193

3.5

245

270

3×120 + 1×70

1.2

1.2

2×0.5

2.5

44

5365

0.153

3.5

285

310

3×150 + 1×70

1.4

1.4

2×0.5

3

49

6468

0.124

3.5

325

345

3×185 + 1×95

1.6

1.4

2×0.5

3

52

7854

0.0991

3.5

375

390

3×240 + 1×120

1.7

1.6

2×0.5

3.5

68

9814

0.0754

3.5

440

450

3×300 + 1×150

1.8

1.7

2×0.5

3.5

71

12781

0.0601

3.5

505

515

3×400 + 1×240

2

1.7

2×0.5

3.5

76

16359

0.047

3.5

570

575

3+2 Core Steel Tape Armoured Cable

Nom. Cross-section of conductor

Insulation Thickness

Inner Covering Thickness

Steel Tape Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

3×4 + 2×2.5

0.7

1

2×0.2

1.5

17.5

855

4.61

3.5

34

45

3×6 + 2×4

0.7

1

2×0.2

1.5

18.9

1009

3.08

3.5

43

57

3×10 + 2×6

0.7

1

2×0.2

2

21.6

1461

1.83

3.5

60

77

3×16 + 2×10

0.7

1

2×0.2

2

24.6

1877

1.15

3.5

83

105

3×25 + 2×16

0.9

1

2×0.2

2

28.7

2583

0.727

3.5

105

125

3×35 + 2×16

0.9

1

2×0.2

2

30.7

3001

0.524

3.5

125

155

3×50 + 2×35

1

1

2×0.2

2

36.2

4392

0.387

3.5

160

185

3×70 + 2×35

1.1

1.2

2×0.2

2.5

40.3

5519

0.268

3.5

200

225

3×95 + 2×50

1.1

1.2

2×0.5

2.5

44.9

7543

0.193

3.5

245

270

3×120 + 2×70

1.2

1.2

2×0.5

2.5

50.3

9203

0.153

3.5

285

310

3×150 + 2×70

1.4

1.4

2×0.5

3

54

10485

0.124

3.5

325

345

3×185 + 2×95

1.6

1.4

2×0.5

3

60.2

13945

0.0991

3.5

375

390

3×240 + 2×120

1.7

1.6

2×0.5

3.5

67.2

15643

0.0754

3.5

440

450

3×300 + 2×150

1.8

1.7

2×0.5

3.5

75.2

18204

0.0601

3.5

505

515

4+1 Core Steel Tape Armoured Cable

Nom. Cross-section of conductor

Insulation Thickness

Inner Covering Thickness

Steel Tape Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

4×4 + 1×2.5

0.7

1

2×0.2

1.5

18.4

565

4.61

3.5

34

45

4×6 + 1×4

0.7

1

2×0.2

1.5

19.8

692

3.08

3.5

43

57

4×10 + 1×6

0.7

1

2×0.2

2

22.8

953

1.83

3.5

60

77

4×16 + 1×10

0.7

1

2×0.2

2

25.8

1318

1.15

3.5

83

105

4×25 + 1×16

0.9

1

2×0.2

2

30.4

1877

0.727

3.5

105

125

4×35 + 1×16

0.9

1

2×0.2

2

34.1

2324

0.524

3.5

125

155

4×50 + 1×25

1

1

2×0.2

2

38.7

3415

0.387

3.5

160

185

4×70 + 1×35

1.1

1.2

2×0.5

2.5

44.2

4432

0.268

3.5

200

225

4×95 + 1×50

1.1

1.2

2×0.5

2.5

49.8

5747

0.193

3.5

245

270

4×120 + 1×70

1.2

1.2

2×0.5

2.5

55.4

7112

0.153

3.5

285

310

4×150 + 1×70

1.4

1.4

2×0.5

3

60.1

8556

0.124

3.5

325

345

4×185 + 1×95

1.6

1.4

2×0.5

3

66.9

10510

0.0991

3.5

375

390

4×240 + 1×120

1.7

1.6

2×0.5

3.5

74.8

13232

0.0754

3.5

440

450

4×300 + 1×150

1.8

1.7

2×0.5

3.5

78.4

16452

0.0601

3.5

505

515

包装与运输We emphasize advancement and introduce new products into the market each year for Factory wholesale 3 Core 4 Core 5 Core 16mm 25mm 35mm 95mm Aluminum/Copper Core Steel Wire PVC/XLPE Underground Power Armoured Cable, How about to start your good enterprise with our corporation? We’re ready, qualified and fulfilled with pride. Let’s start our new organization with new wave.
Factory wholesale China Copper Wire and Wire, To create more creative goods, maintain high-quality products and solutions and update not only our goods but ourselves so as to keep us ahead of the world, and the last but most vital one: to make every client satisfied with everything we offer you and to grow stronger together. To be the real winner, starts here!


  • Previous:
  • Next:

  • Write your message here and send it to us