Flame Retardant Fire Resistant Armoured and Unarmoured Power Cable
To frequently enhance the management process by virtue of your rule of “sincerely, good religion and good quality are the base of company development”, we greatly absorb the essence of associated solutions internationally, and regularly produce new goods to meet the needs of shoppers for Flame Retardant Fire Resistant Armoured and Unarmoured Power Cable, We maintain timely delivery schedules, modern designs, high-quality and transparency for our clients. Our moto would be to deliver high quality solutions within stipulated time.
To frequently enhance the management process by virtue of your rule of “sincerely, good religion and good quality are the base of company development”, we greatly absorb the essence of associated solutions internationally, and regularly produce new goods to meet the needs of shoppers for China PVC Insulated Power Cable and Fire-Resistant Power Cable, Our factory is equipped with complete facility in 10000 square meters, which makes us be able to satisfy the producing and sales for most auto part solutions. Our advantage is full category, high quality and competitive price! Based on that, our goods win a high admiration both at home and abroad.
Application
Indoors cable trunking, outdoors for power stations, industry and switchgear as well as for urban supply networks, if mechanical damage is unlikely
Constrution
Characteristics
Rated voltage: 0.6/1kV
1.during normal operation of cable, the maximum conductor temperature shall be 70℃ for PVC insulation and 90℃ for XLPE insulation.
2.Maximum temperature of conductor during short circuit (maximum duration not exceeding 5 seconds) : PVC insulation — 160℃ for conductor cross section ≤300mm2, 140℃ for conductor cross section > 300mm2; Crosslinked PVC insulation at 250℃.
3.When laying cables, the ambient temperature shall not be less than 0℃, and the minimum allowable bending radius is as follows:
Single core cable: unarmored 20D, armored 15D
Multi-core cable: 15D for unarmored, 12D for armored
Where: D- actual outer diameter of cable.
4.Cable breaking force:
Aluminum core cable: 40×S (N)
Copper core cable: 70×S (N)
Note: S is the total cross-sectional area of the conductor
Standards
IEC 60502-1, GB/T 12706.1
Parameters
Single Core Power Cable |
||||||||
Nom. Cross-section of conductor |
Insulation Thickness |
Sheath Thickness |
Approx. O.D. |
Approx Weight |
Max. D.C. Resistance of Conductor (20°C) |
Test Voltage A.C |
Current Rating |
|
mm2 |
mm |
mm |
mm |
kg/km |
Ω/km |
kV/5min |
In air(A) |
In soil(A) |
1×1.5 |
0.7 |
1.4 |
6 |
53 |
12.1 |
3.5 |
22 |
33 |
1×2.5 |
0.7 |
1.4 |
6 |
68 |
7.41 |
3.5 |
31 |
43 |
1×4 |
0.7 |
1.4 |
7 |
87 |
4.61 |
3.5 |
41 |
56 |
1×6 |
0.7 |
1.4 |
7 |
110 |
3.08 |
3.5 |
52 |
70 |
1×10 |
0.7 |
1.4 |
8 |
155 |
1.83 |
3.5 |
71 |
94 |
1×16 |
0.7 |
1.4 |
9 |
220 |
1.15 |
3.5 |
92 |
120 |
1×25 |
0.9 |
1.4 |
10 |
345 |
0.727 |
3.5 |
120 |
155 |
1×35 |
0.9 |
1.4 |
12 |
424 |
0.524 |
3.5 |
150 |
185 |
1×50 |
1 |
1.4 |
13 |
555 |
0.387 |
3.5 |
180 |
220 |
1×70 |
1.1 |
1.4 |
14 |
770 |
0.268 |
3.5 |
230 |
270 |
1×95 |
1.1 |
1.5 |
16 |
1040 |
0.193 |
3.5 |
285 |
320 |
1×120 |
1.2 |
1.5 |
18 |
1290 |
0.153 |
3.5 |
335 |
365 |
1×150 |
1.4 |
1.6 |
20 |
1590 |
0.124 |
3.5 |
385 |
410 |
1×185 |
1.6 |
1.6 |
22 |
1944 |
0.0991 |
3.5 |
450 |
465 |
1×240 |
1.7 |
1.7 |
25 |
2510 |
0.0754 |
3.5 |
535 |
540 |
1×300 |
1.8 |
1.8 |
27 |
3042 |
0.0601 |
3.5 |
620 |
610 |
1×400 |
2 |
1.9 |
31 |
3869 |
0.047 |
3.5 |
720 |
695 |
1×500 |
2.2 |
2.1 |
35 |
4910 |
0.0366 |
3.5 |
835 |
780 |
1×630 |
2.4 |
2.2 |
40 |
6220 |
0.0283 |
3.5 |
960 |
880 |
1×800 |
2.6 |
2.4 |
45 |
7870 |
0.0221 |
3.5 |
1110 |
970 |
1×1000 |
2.8 |
2.6 |
51 |
9804 |
0.0176 |
3.5 |
1230 |
1060 |
2 Core Power Cable |
||||||||
Nom. Cross-section of conductor |
Insulation Thickness |
Sheath Thickness |
Approx. O.D. |
Approx Weight |
Max. D.C. Resistance of Conductor (20°C) |
Test Voltage A.C |
Current Rating |
|
mm2 |
mm |
mm |
mm |
kg/km |
Ω/km |
kV/5min |
In air(A) |
In soil(A) |
2×2.5 |
0.7 |
1.8 |
11.8 |
151 |
7.41 |
3.5 |
26 |
35 |
2×4 |
0.7 |
1.8 |
12.7 |
198 |
4.61 |
3.5 |
34 |
45 |
2×6 |
0.7 |
1.8 |
13.7 |
250 |
3.08 |
3.5 |
43 |
57 |
2×10 |
0.7 |
1.8 |
15 |
374 |
1.83 |
3.5 |
60 |
77 |
2×16 |
0.7 |
1.8 |
17 |
518 |
1.15 |
3.5 |
83 |
105 |
2×25 |
0.9 |
1.8 |
20 |
772 |
0.727 |
3.5 |
105 |
125 |
2×35 |
0.9 |
1.8 |
22 |
1006 |
0.524 |
3.5 |
125 |
155 |
2×50 |
1 |
1.8 |
20 |
1365 |
0.387 |
3.5 |
160 |
185 |
2×70 |
1.1 |
1.8 |
21 |
1872 |
0.268 |
3.5 |
200 |
225 |
2×95 |
1.1 |
1.8 |
24 |
2475 |
0.193 |
3.5 |
245 |
270 |
2×120 |
1.2 |
1.8 |
27 |
3089 |
0.153 |
3.5 |
285 |
310 |
2×150 |
1.4 |
1.9 |
30 |
3834 |
0.124 |
3.5 |
325 |
345 |
3 Core Power Cable |
||||||||
Nom. Cross-section of conductor |
Insulation Thickness |
Sheath Thickness |
Approx. O.D. |
Approx Weight |
Max. D.C. Resistance of Conductor (20°C) |
Test Voltage A.C |
Current Rating |
|
mm2 |
mm |
mm |
mm |
kg/km |
Ω/km |
kV/5min |
In air(A) |
In soil(A) |
3×1.5 |
0.7 |
1.5 |
10 |
145 |
12.1 |
3.5 |
20 |
27 |
3×2.5 |
0.7 |
1.5 |
11 |
185 |
7.41 |
3.5 |
26 |
35 |
3×4 |
0.7 |
1.5 |
12 |
250 |
4.61 |
3.5 |
34 |
45 |
3×6 |
0.7 |
1.5 |
13 |
320 |
3.08 |
3.5 |
43 |
57 |
3×10 |
0.7 |
1.8 |
16 |
450 |
1.83 |
3.5 |
60 |
77 |
3×16 |
0.7 |
1.8 |
18 |
640 |
1.15 |
3.5 |
83 |
105 |
3×25 |
0.9 |
1.8 |
21 |
940 |
0.727 |
3.5 |
105 |
125 |
3×35 |
0.9 |
1.8 |
23 |
1260 |
0.524 |
3.5 |
125 |
155 |
3×50 |
1 |
1.8 |
23 |
1670 |
0.387 |
3.5 |
160 |
185 |
3×70 |
1.1 |
1.8 |
26 |
2280 |
0.268 |
3.5 |
200 |
225 |
3×95 |
1.1 |
1.9 |
30 |
3020 |
0.193 |
3.5 |
245 |
270 |
3×120 |
1.2 |
2 |
32 |
3790 |
0.153 |
3.5 |
285 |
310 |
3×150 |
1.4 |
2.2 |
37 |
4750 |
0.124 |
3.5 |
325 |
345 |
3×185 |
1.6 |
2.3 |
41 |
5654 |
0.0991 |
3.5 |
375 |
390 |
3×240 |
1.7 |
2.4 |
46 |
7243 |
0.0754 |
3.5 |
440 |
450 |
3×300 |
1.8 |
2.6 |
51 |
9465 |
0.0601 |
3.5 |
505 |
515 |
3×400 |
2 |
3 |
64 |
12066 |
0.047 |
3.5 |
570 |
575 |
4 Core Power Cable |
||||||||
Nom. Cross-section of conductor |
Insulation Thickness |
Sheath Thickness |
Approx. O.D. |
Approx Weight |
Max. D.C. Resistance of Conductor (20°C) |
Test Voltage A.C |
Current Rating |
|
mm2 |
mm |
mm |
mm |
kg/km |
Ω/km |
kV/5min |
In air(A) |
In soil(A) |
4×4 |
0.7 |
1.8 |
13 |
253 |
4.61 |
3.5 |
34 |
45 |
4×6 |
0.7 |
1.8 |
14 |
337 |
3.08 |
3.5 |
43 |
57 |
4×10 |
0.7 |
1.8 |
17 |
501 |
1.83 |
3.5 |
60 |
77 |
4×16 |
0.7 |
1.8 |
20 |
778 |
1.15 |
3.5 |
83 |
105 |
4×25 |
0.9 |
1.8 |
23 |
1160 |
0.727 |
3.5 |
105 |
125 |
4×35 |
0.9 |
1.8 |
25 |
1554 |
0.524 |
3.5 |
125 |
155 |
4×50 |
1 |
1.8 |
23 |
2148 |
0.387 |
3.5 |
160 |
185 |
4×70 |
1.1 |
1.8 |
27 |
2928 |
0.268 |
3.5 |
200 |
225 |
4×95 |
1.1 |
1.9 |
31 |
3854 |
0.193 |
3.5 |
245 |
270 |
4×120 |
1.2 |
2 |
33 |
4925 |
0.153 |
3.5 |
285 |
310 |
4×150 |
1.4 |
2.2 |
38 |
6238 |
0.124 |
3.5 |
325 |
345 |
4×185 |
1.6 |
2.3 |
42 |
7562 |
0.0991 |
3.5 |
375 |
390 |
4×240 |
1.7 |
2.5 |
47 |
9836 |
0.0754 |
3.5 |
440 |
450 |
4×300 |
1.8 |
2.6 |
52 |
12550 |
0.0601 |
3.5 |
505 |
515 |
4×400 |
2 |
3.1 |
66 |
15929 |
0.047 |
3.5 |
570 |
575 |
5 Core Power Cable |
||||||||
Nom. Cross-section of conductor |
Insulation Thickness |
Sheath Thickness |
Approx. O.D. |
Approx Weight |
Max. D.C. Resistance of Conductor (20°C) |
Test Voltage A.C |
Current Rating |
|
mm2 |
mm |
mm |
mm |
kg/km |
Ω/km |
kV/5min |
In air(A) |
In soil(A) |
5×4 |
0.7 |
1.8 |
14.5 |
349 |
4.61 |
3.5 |
34 |
45 |
5×6 |
0.7 |
1.8 |
15.8 |
460 |
3.08 |
3.5 |
43 |
57 |
5×10 |
0.7 |
1.8 |
19 |
699 |
1.83 |
3.5 |
60 |
77 |
5×16 |
0.7 |
1.8 |
22 |
1013 |
1.15 |
3.5 |
83 |
105 |
5×25 |
0.9 |
1.8 |
25 |
1566 |
0.727 |
3.5 |
105 |
125 |
5×35 |
0.9 |
1.9 |
28 |
2083 |
0.524 |
3.5 |
125 |
155 |
5×50 |
1 |
2 |
31 |
2921 |
0.387 |
3.5 |
160 |
185 |
5×70 |
1.1 |
2.1 |
36 |
3974 |
0.268 |
3.5 |
200 |
225 |
5×95 |
1.1 |
2.2 |
39 |
5297 |
0.193 |
3.5 |
245 |
270 |
5×120 |
1.2 |
2.4 |
44 |
6638 |
0.153 |
3.5 |
285 |
310 |
5×150 |
1.4 |
2.5 |
49 |
8290 |
0.124 |
3.5 |
325 |
345 |
5×185 |
1.6 |
2.7 |
55 |
10215 |
0.0991 |
3.5 |
375 |
390 |
5×240 |
1.7 |
3 |
64 |
13130 |
0.0754 |
3.5 |
440 |
450 |
5×300 |
1.8 |
3.2 |
70 |
16670 |
0.0601 |
3.5 |
505 |
515 |
3+1 Core Power Cable |
||||||||
Nom. Cross-section of conductor |
Insulation Thickness |
Sheath Thickness |
Approx. O.D. |
Approx Weight |
Max. D.C. Resistance of Conductor (20°C) |
Test Voltage A.C |
Current Rating |
|
mm2 |
mm |
mm |
mm |
kg/km |
Ω/km |
kV/5min |
In air(A) |
In soil(A) |
3×4+1×2.5 |
0.7 |
1.8 |
13 |
236 |
4.61 |
3.5 |
34 |
45 |
3×6+1×4 |
0.7 |
1.8 |
14 |
316 |
3.08 |
3.5 |
43 |
57 |
3×10+1×6 |
0.7 |
1.8 |
17 |
461 |
1.83 |
3.5 |
60 |
77 |
3×16+1×10 |
0.7 |
1.8 |
19 |
679 |
1.15 |
3.5 |
83 |
105 |
3×25+1×16 |
0.9 |
1.8 |
22 |
1065 |
0.727 |
3.5 |
105 |
125 |
3×35+1×16 |
0.9 |
1.8 |
24 |
1360 |
0.524 |
3.5 |
125 |
155 |
3×50+1×25 |
1 |
1.8 |
25 |
1901 |
0.387 |
3.5 |
160 |
185 |
3×70+1×35 |
1.1 |
1.9 |
28 |
2585 |
0.268 |
3.5 |
200 |
225 |
3×95+1×50 |
1.1 |
2 |
32 |
3518 |
0.193 |
3.5 |
245 |
270 |
3×120+1×70 |
1.2 |
2.1 |
35 |
4443 |
0.153 |
3.5 |
285 |
310 |
3×150+1×70 |
1.4 |
2.2 |
40 |
5326 |
0.124 |
3.5 |
325 |
345 |
3×185+1×95 |
1.6 |
2.4 |
43 |
8501 |
0.0991 |
3.5 |
375 |
390 |
3×240+1×120 |
1.7 |
2.5 |
48 |
11155 |
0.0754 |
3.5 |
440 |
450 |
3×300+1×150 |
1.8 |
2.7 |
54 |
14470 |
0.0601 |
3.5 |
505 |
515 |
3×400+1×240 |
2 |
3.1 |
66 |
309 |
0.047 |
3.5 |
570 |
575 |
3+2 Core Power Cable |
||||||||
Nom. Cross-section of conductor |
Insulation Thickness |
Sheath Thickness |
Approx. O.D. |
Approx Weight |
Max. D.C. Resistance of Conductor (20°C) |
Test Voltage A.C |
Current Rating |
|
mm2 |
mm |
mm |
mm |
kg/km |
Ω/km |
kV/5min |
In air(A) |
In soil(A) |
3×4+2×2.5 |
0.7 |
1.8 |
13.9 |
413 |
4.61 |
3.5 |
34 |
45 |
3×6+2×4 |
0.7 |
1.8 |
15.3 |
6682 |
3.08 |
3.5 |
43 |
57 |
3×10+2×6 |
0.7 |
1.8 |
18 |
603 |
1.83 |
3.5 |
60 |
77 |
3×16+2×10 |
0.7 |
1.8 |
21 |
888 |
1.15 |
3.5 |
83 |
105 |
3×25+2×16 |
0.9 |
1.8 |
24 |
1342 |
0.727 |
3.5 |
105 |
125 |
3×35+2×16 |
0.9 |
1.8 |
26 |
1647 |
0.524 |
3.5 |
125 |
155 |
3×50+2×35 |
1 |
1.9 |
29 |
2386 |
0.387 |
3.5 |
160 |
185 |
3×70+2×35 |
1.1 |
2 |
32 |
3201 |
0.268 |
3.5 |
200 |
225 |
3×95+2×50 |
1.1 |
2.1 |
36 |
4269 |
0.193 |
3.5 |
245 |
270 |
3×120+2×70 |
1.2 |
2.3 |
41 |
5437 |
0.153 |
3.5 |
285 |
310 |
3×150+2×70 |
1.4 |
2.4 |
44 |
6519 |
0.124 |
3.5 |
325 |
345 |
3×185+2×95 |
1.6 |
2.5 |
49 |
8101 |
0.0991 |
3.5 |
375 |
390 |
3×240+2×120 |
1.7 |
2.7 |
54 |
10340 |
0.0754 |
3.5 |
440 |
450 |
3×300+2×150 |
1.8 |
2.8 |
56 |
12810 |
0.0601 |
3.5 |
505 |
515 |
4+1 Core Power Cable |
||||||||
Nom. Cross-section of conductor |
Insulation Thickness |
Sheath Thickness |
Approx. O.D. |
Approx Weight |
Max. D.C. Resistance of Conductor (20°C) |
Test Voltage A.C |
Current Rating |
|
mm2 |
mm |
mm |
mm |
kg/km |
Ω/km |
kV/5min |
In air(A) |
In soil(A) |
4×4+1×2.5 |
0.7 |
1.8 |
14.5 |
331 |
4.61 |
3.5 |
34 |
45 |
4×6+1×4 |
0.7 |
1.8 |
15.9 |
435 |
3.08 |
3.5 |
43 |
57 |
4×10+1×6 |
0.7 |
1.8 |
18 |
649 |
1.83 |
3.5 |
60 |
77 |
4×16+1×10 |
0.7 |
1.8 |
21 |
965 |
1.15 |
3.5 |
83 |
105 |
4×25+1×16 |
0.9 |
1.8 |
25 |
1456 |
0.727 |
3.5 |
105 |
125 |
4×35+1×16 |
0.9 |
1.8 |
27 |
1863 |
0.524 |
3.5 |
125 |
155 |
4×50+1×25 |
1 |
1.9 |
29 |
2633 |
0.387 |
3.5 |
160 |
185 |
4×70+1×35 |
1.1 |
2 |
32 |
3565 |
0.268 |
3.5 |
200 |
225 |
4×95+1×50 |
1.1 |
2.1 |
36 |
4735 |
0.193 |
3.5 |
245 |
270 |
4×120+1×70 |
1.2 |
2.3 |
41 |
5977 |
0.153 |
3.5 |
285 |
310 |
4×150+1×70 |
1.4 |
2.4 |
44 |
7276 |
0.124 |
3.5 |
325 |
345 |
4×185+1×95 |
1.6 |
2.5 |
49 |
9055 |
0.0991 |
3.5 |
375 |
390 |
4×240+1×120 |
1.7 |
2.7 |
54 |
11567 |
0.0754 |
3.5 |
440 |
450 |
4×300+1×150 |
1.8 |
3.1 |
66 |
14321 |
0.0601 |
3.5 |
505 |
515 |
To frequently enhance the management process by virtue of your rule of “sincerely, good religion and good quality are the base of company development”, we greatly absorb the essence of associated solutions internationally, and regularly produce new goods to meet the needs of shoppers for Free sample for Flame Retardant Fire Resistant Armoured and Unarmoured Power Cable, We maintain timely delivery schedules, modern designs, high-quality and transparency for our clients. Our moto would be to deliver high quality solutions within stipulated time.
Free sample for China PVC Insulated Power Cable and Fire-Resistant Power Cable, Our factory is equipped with complete facility in 10000 square meters, which makes us be able to satisfy the producing and sales for most auto part solutions. Our advantage is full category, high quality and competitive price! Based on that, our goods win a high admiration both at home and abroad.