New Delivery for 0.6/1kv Electric Aluminum Conductor PVC/XLPE/PE Insulated PVC Sheathed Low/Medium Voltag Electrical Power Cable
We generally believe that one’s character decides products’ excellent, the details decides products’ good quality ,with all the REALISTIC,EFFICIENT AND INNOVATIVE group spirit for New Delivery for 0.6/1kv Electric Aluminum Conductor PVC/XLPE/PE Insulated PVC Sheathed Low/Medium Voltag Electrical Power Cable, We warmly welcome merchants from home and abroad to call us and establish business relationship with us, and we will do our best to serve you.
We generally believe that one’s character decides products’ excellent, the details decides products’ good quality ,with all the REALISTIC,EFFICIENT AND INNOVATIVE group spirit for China Power Cable and Electrical Power Cable, Our qualified engineering team will usually be prepared to serve you for consultation and feedback. We have been able to also deliver you with absolutely free samples to meet your needs. Best efforts might be made to offer you the ideal service and products and solutions. For anyone who is interested in our company and items, you should make contact with us by sending us emails or contact us right away. In order to know our solutions and organization. ar more, you can come to our factory to determine it. We’ve been gonna usually welcome guests from around the globe to our corporation. o create small business relations with us. You should definitely feel no cost to speak to us for enterprise. nd we believe we’re likely to share the most effective trading practical experience with all our merchants.
Application
Indoors cable trunking, outdoors for power stations, industry and switchgear as well as for urban supply networks, if mechanical damage is unlikely
Constrution
Characteristics
Rated voltage: 0.6/1kV
1.during normal operation of cable, the maximum conductor temperature shall be 70℃ for PVC insulation and 90℃ for XLPE insulation.
2.Maximum temperature of conductor during short circuit (maximum duration not exceeding 5 seconds) : PVC insulation — 160℃ for conductor cross section ≤300mm2, 140℃ for conductor cross section > 300mm2; Crosslinked PVC insulation at 250℃.
3.When laying cables, the ambient temperature shall not be less than 0℃, and the minimum allowable bending radius is as follows:
Single core cable: unarmored 20D, armored 15D
Multi-core cable: 15D for unarmored, 12D for armored
Where: D- actual outer diameter of cable.
4.Cable breaking force:
Aluminum core cable: 40×S (N)
Copper core cable: 70×S (N)
Note: S is the total cross-sectional area of the conductor
Standards
IEC 60502-1, GB/T 12706.1
Parameters
Single Core Power Cable |
||||||||
Nom. Cross-section of conductor |
Insulation Thickness |
Sheath Thickness |
Approx. O.D. |
Approx Weight |
Max. D.C. Resistance of Conductor (20°C) |
Test Voltage A.C |
Current Rating |
|
mm2 |
mm |
mm |
mm |
kg/km |
Ω/km |
kV/5min |
In air(A) |
In soil(A) |
1×1.5 |
0.7 |
1.4 |
6 |
53 |
12.1 |
3.5 |
22 |
33 |
1×2.5 |
0.7 |
1.4 |
6 |
68 |
7.41 |
3.5 |
31 |
43 |
1×4 |
0.7 |
1.4 |
7 |
87 |
4.61 |
3.5 |
41 |
56 |
1×6 |
0.7 |
1.4 |
7 |
110 |
3.08 |
3.5 |
52 |
70 |
1×10 |
0.7 |
1.4 |
8 |
155 |
1.83 |
3.5 |
71 |
94 |
1×16 |
0.7 |
1.4 |
9 |
220 |
1.15 |
3.5 |
92 |
120 |
1×25 |
0.9 |
1.4 |
10 |
345 |
0.727 |
3.5 |
120 |
155 |
1×35 |
0.9 |
1.4 |
12 |
424 |
0.524 |
3.5 |
150 |
185 |
1×50 |
1 |
1.4 |
13 |
555 |
0.387 |
3.5 |
180 |
220 |
1×70 |
1.1 |
1.4 |
14 |
770 |
0.268 |
3.5 |
230 |
270 |
1×95 |
1.1 |
1.5 |
16 |
1040 |
0.193 |
3.5 |
285 |
320 |
1×120 |
1.2 |
1.5 |
18 |
1290 |
0.153 |
3.5 |
335 |
365 |
1×150 |
1.4 |
1.6 |
20 |
1590 |
0.124 |
3.5 |
385 |
410 |
1×185 |
1.6 |
1.6 |
22 |
1944 |
0.0991 |
3.5 |
450 |
465 |
1×240 |
1.7 |
1.7 |
25 |
2510 |
0.0754 |
3.5 |
535 |
540 |
1×300 |
1.8 |
1.8 |
27 |
3042 |
0.0601 |
3.5 |
620 |
610 |
1×400 |
2 |
1.9 |
31 |
3869 |
0.047 |
3.5 |
720 |
695 |
1×500 |
2.2 |
2.1 |
35 |
4910 |
0.0366 |
3.5 |
835 |
780 |
1×630 |
2.4 |
2.2 |
40 |
6220 |
0.0283 |
3.5 |
960 |
880 |
1×800 |
2.6 |
2.4 |
45 |
7870 |
0.0221 |
3.5 |
1110 |
970 |
1×1000 |
2.8 |
2.6 |
51 |
9804 |
0.0176 |
3.5 |
1230 |
1060 |
2 Core Power Cable |
||||||||
Nom. Cross-section of conductor |
Insulation Thickness |
Sheath Thickness |
Approx. O.D. |
Approx Weight |
Max. D.C. Resistance of Conductor (20°C) |
Test Voltage A.C |
Current Rating |
|
mm2 |
mm |
mm |
mm |
kg/km |
Ω/km |
kV/5min |
In air(A) |
In soil(A) |
2×2.5 |
0.7 |
1.8 |
11.8 |
151 |
7.41 |
3.5 |
26 |
35 |
2×4 |
0.7 |
1.8 |
12.7 |
198 |
4.61 |
3.5 |
34 |
45 |
2×6 |
0.7 |
1.8 |
13.7 |
250 |
3.08 |
3.5 |
43 |
57 |
2×10 |
0.7 |
1.8 |
15 |
374 |
1.83 |
3.5 |
60 |
77 |
2×16 |
0.7 |
1.8 |
17 |
518 |
1.15 |
3.5 |
83 |
105 |
2×25 |
0.9 |
1.8 |
20 |
772 |
0.727 |
3.5 |
105 |
125 |
2×35 |
0.9 |
1.8 |
22 |
1006 |
0.524 |
3.5 |
125 |
155 |
2×50 |
1 |
1.8 |
20 |
1365 |
0.387 |
3.5 |
160 |
185 |
2×70 |
1.1 |
1.8 |
21 |
1872 |
0.268 |
3.5 |
200 |
225 |
2×95 |
1.1 |
1.8 |
24 |
2475 |
0.193 |
3.5 |
245 |
270 |
2×120 |
1.2 |
1.8 |
27 |
3089 |
0.153 |
3.5 |
285 |
310 |
2×150 |
1.4 |
1.9 |
30 |
3834 |
0.124 |
3.5 |
325 |
345 |
3 Core Power Cable |
||||||||
Nom. Cross-section of conductor |
Insulation Thickness |
Sheath Thickness |
Approx. O.D. |
Approx Weight |
Max. D.C. Resistance of Conductor (20°C) |
Test Voltage A.C |
Current Rating |
|
mm2 |
mm |
mm |
mm |
kg/km |
Ω/km |
kV/5min |
In air(A) |
In soil(A) |
3×1.5 |
0.7 |
1.5 |
10 |
145 |
12.1 |
3.5 |
20 |
27 |
3×2.5 |
0.7 |
1.5 |
11 |
185 |
7.41 |
3.5 |
26 |
35 |
3×4 |
0.7 |
1.5 |
12 |
250 |
4.61 |
3.5 |
34 |
45 |
3×6 |
0.7 |
1.5 |
13 |
320 |
3.08 |
3.5 |
43 |
57 |
3×10 |
0.7 |
1.8 |
16 |
450 |
1.83 |
3.5 |
60 |
77 |
3×16 |
0.7 |
1.8 |
18 |
640 |
1.15 |
3.5 |
83 |
105 |
3×25 |
0.9 |
1.8 |
21 |
940 |
0.727 |
3.5 |
105 |
125 |
3×35 |
0.9 |
1.8 |
23 |
1260 |
0.524 |
3.5 |
125 |
155 |
3×50 |
1 |
1.8 |
23 |
1670 |
0.387 |
3.5 |
160 |
185 |
3×70 |
1.1 |
1.8 |
26 |
2280 |
0.268 |
3.5 |
200 |
225 |
3×95 |
1.1 |
1.9 |
30 |
3020 |
0.193 |
3.5 |
245 |
270 |
3×120 |
1.2 |
2 |
32 |
3790 |
0.153 |
3.5 |
285 |
310 |
3×150 |
1.4 |
2.2 |
37 |
4750 |
0.124 |
3.5 |
325 |
345 |
3×185 |
1.6 |
2.3 |
41 |
5654 |
0.0991 |
3.5 |
375 |
390 |
3×240 |
1.7 |
2.4 |
46 |
7243 |
0.0754 |
3.5 |
440 |
450 |
3×300 |
1.8 |
2.6 |
51 |
9465 |
0.0601 |
3.5 |
505 |
515 |
3×400 |
2 |
3 |
64 |
12066 |
0.047 |
3.5 |
570 |
575 |
4 Core Power Cable |
||||||||
Nom. Cross-section of conductor |
Insulation Thickness |
Sheath Thickness |
Approx. O.D. |
Approx Weight |
Max. D.C. Resistance of Conductor (20°C) |
Test Voltage A.C |
Current Rating |
|
mm2 |
mm |
mm |
mm |
kg/km |
Ω/km |
kV/5min |
In air(A) |
In soil(A) |
4×4 |
0.7 |
1.8 |
13 |
253 |
4.61 |
3.5 |
34 |
45 |
4×6 |
0.7 |
1.8 |
14 |
337 |
3.08 |
3.5 |
43 |
57 |
4×10 |
0.7 |
1.8 |
17 |
501 |
1.83 |
3.5 |
60 |
77 |
4×16 |
0.7 |
1.8 |
20 |
778 |
1.15 |
3.5 |
83 |
105 |
4×25 |
0.9 |
1.8 |
23 |
1160 |
0.727 |
3.5 |
105 |
125 |
4×35 |
0.9 |
1.8 |
25 |
1554 |
0.524 |
3.5 |
125 |
155 |
4×50 |
1 |
1.8 |
23 |
2148 |
0.387 |
3.5 |
160 |
185 |
4×70 |
1.1 |
1.8 |
27 |
2928 |
0.268 |
3.5 |
200 |
225 |
4×95 |
1.1 |
1.9 |
31 |
3854 |
0.193 |
3.5 |
245 |
270 |
4×120 |
1.2 |
2 |
33 |
4925 |
0.153 |
3.5 |
285 |
310 |
4×150 |
1.4 |
2.2 |
38 |
6238 |
0.124 |
3.5 |
325 |
345 |
4×185 |
1.6 |
2.3 |
42 |
7562 |
0.0991 |
3.5 |
375 |
390 |
4×240 |
1.7 |
2.5 |
47 |
9836 |
0.0754 |
3.5 |
440 |
450 |
4×300 |
1.8 |
2.6 |
52 |
12550 |
0.0601 |
3.5 |
505 |
515 |
4×400 |
2 |
3.1 |
66 |
15929 |
0.047 |
3.5 |
570 |
575 |
5 Core Power Cable |
||||||||
Nom. Cross-section of conductor |
Insulation Thickness |
Sheath Thickness |
Approx. O.D. |
Approx Weight |
Max. D.C. Resistance of Conductor (20°C) |
Test Voltage A.C |
Current Rating |
|
mm2 |
mm |
mm |
mm |
kg/km |
Ω/km |
kV/5min |
In air(A) |
In soil(A) |
5×4 |
0.7 |
1.8 |
14.5 |
349 |
4.61 |
3.5 |
34 |
45 |
5×6 |
0.7 |
1.8 |
15.8 |
460 |
3.08 |
3.5 |
43 |
57 |
5×10 |
0.7 |
1.8 |
19 |
699 |
1.83 |
3.5 |
60 |
77 |
5×16 |
0.7 |
1.8 |
22 |
1013 |
1.15 |
3.5 |
83 |
105 |
5×25 |
0.9 |
1.8 |
25 |
1566 |
0.727 |
3.5 |
105 |
125 |
5×35 |
0.9 |
1.9 |
28 |
2083 |
0.524 |
3.5 |
125 |
155 |
5×50 |
1 |
2 |
31 |
2921 |
0.387 |
3.5 |
160 |
185 |
5×70 |
1.1 |
2.1 |
36 |
3974 |
0.268 |
3.5 |
200 |
225 |
5×95 |
1.1 |
2.2 |
39 |
5297 |
0.193 |
3.5 |
245 |
270 |
5×120 |
1.2 |
2.4 |
44 |
6638 |
0.153 |
3.5 |
285 |
310 |
5×150 |
1.4 |
2.5 |
49 |
8290 |
0.124 |
3.5 |
325 |
345 |
5×185 |
1.6 |
2.7 |
55 |
10215 |
0.0991 |
3.5 |
375 |
390 |
5×240 |
1.7 |
3 |
64 |
13130 |
0.0754 |
3.5 |
440 |
450 |
5×300 |
1.8 |
3.2 |
70 |
16670 |
0.0601 |
3.5 |
505 |
515 |
3+1 Core Power Cable |
||||||||
Nom. Cross-section of conductor |
Insulation Thickness |
Sheath Thickness |
Approx. O.D. |
Approx Weight |
Max. D.C. Resistance of Conductor (20°C) |
Test Voltage A.C |
Current Rating |
|
mm2 |
mm |
mm |
mm |
kg/km |
Ω/km |
kV/5min |
In air(A) |
In soil(A) |
3×4+1×2.5 |
0.7 |
1.8 |
13 |
236 |
4.61 |
3.5 |
34 |
45 |
3×6+1×4 |
0.7 |
1.8 |
14 |
316 |
3.08 |
3.5 |
43 |
57 |
3×10+1×6 |
0.7 |
1.8 |
17 |
461 |
1.83 |
3.5 |
60 |
77 |
3×16+1×10 |
0.7 |
1.8 |
19 |
679 |
1.15 |
3.5 |
83 |
105 |
3×25+1×16 |
0.9 |
1.8 |
22 |
1065 |
0.727 |
3.5 |
105 |
125 |
3×35+1×16 |
0.9 |
1.8 |
24 |
1360 |
0.524 |
3.5 |
125 |
155 |
3×50+1×25 |
1 |
1.8 |
25 |
1901 |
0.387 |
3.5 |
160 |
185 |
3×70+1×35 |
1.1 |
1.9 |
28 |
2585 |
0.268 |
3.5 |
200 |
225 |
3×95+1×50 |
1.1 |
2 |
32 |
3518 |
0.193 |
3.5 |
245 |
270 |
3×120+1×70 |
1.2 |
2.1 |
35 |
4443 |
0.153 |
3.5 |
285 |
310 |
3×150+1×70 |
1.4 |
2.2 |
40 |
5326 |
0.124 |
3.5 |
325 |
345 |
3×185+1×95 |
1.6 |
2.4 |
43 |
8501 |
0.0991 |
3.5 |
375 |
390 |
3×240+1×120 |
1.7 |
2.5 |
48 |
11155 |
0.0754 |
3.5 |
440 |
450 |
3×300+1×150 |
1.8 |
2.7 |
54 |
14470 |
0.0601 |
3.5 |
505 |
515 |
3×400+1×240 |
2 |
3.1 |
66 |
309 |
0.047 |
3.5 |
570 |
575 |
3+2 Core Power Cable |
||||||||
Nom. Cross-section of conductor |
Insulation Thickness |
Sheath Thickness |
Approx. O.D. |
Approx Weight |
Max. D.C. Resistance of Conductor (20°C) |
Test Voltage A.C |
Current Rating |
|
mm2 |
mm |
mm |
mm |
kg/km |
Ω/km |
kV/5min |
In air(A) |
In soil(A) |
3×4+2×2.5 |
0.7 |
1.8 |
13.9 |
413 |
4.61 |
3.5 |
34 |
45 |
3×6+2×4 |
0.7 |
1.8 |
15.3 |
6682 |
3.08 |
3.5 |
43 |
57 |
3×10+2×6 |
0.7 |
1.8 |
18 |
603 |
1.83 |
3.5 |
60 |
77 |
3×16+2×10 |
0.7 |
1.8 |
21 |
888 |
1.15 |
3.5 |
83 |
105 |
3×25+2×16 |
0.9 |
1.8 |
24 |
1342 |
0.727 |
3.5 |
105 |
125 |
3×35+2×16 |
0.9 |
1.8 |
26 |
1647 |
0.524 |
3.5 |
125 |
155 |
3×50+2×35 |
1 |
1.9 |
29 |
2386 |
0.387 |
3.5 |
160 |
185 |
3×70+2×35 |
1.1 |
2 |
32 |
3201 |
0.268 |
3.5 |
200 |
225 |
3×95+2×50 |
1.1 |
2.1 |
36 |
4269 |
0.193 |
3.5 |
245 |
270 |
3×120+2×70 |
1.2 |
2.3 |
41 |
5437 |
0.153 |
3.5 |
285 |
310 |
3×150+2×70 |
1.4 |
2.4 |
44 |
6519 |
0.124 |
3.5 |
325 |
345 |
3×185+2×95 |
1.6 |
2.5 |
49 |
8101 |
0.0991 |
3.5 |
375 |
390 |
3×240+2×120 |
1.7 |
2.7 |
54 |
10340 |
0.0754 |
3.5 |
440 |
450 |
3×300+2×150 |
1.8 |
2.8 |
56 |
12810 |
0.0601 |
3.5 |
505 |
515 |
4+1 Core Power Cable |
||||||||
Nom. Cross-section of conductor |
Insulation Thickness |
Sheath Thickness |
Approx. O.D. |
Approx Weight |
Max. D.C. Resistance of Conductor (20°C) |
Test Voltage A.C |
Current Rating |
|
mm2 |
mm |
mm |
mm |
kg/km |
Ω/km |
kV/5min |
In air(A) |
In soil(A) |
4×4+1×2.5 |
0.7 |
1.8 |
14.5 |
331 |
4.61 |
3.5 |
34 |
45 |
4×6+1×4 |
0.7 |
1.8 |
15.9 |
435 |
3.08 |
3.5 |
43 |
57 |
4×10+1×6 |
0.7 |
1.8 |
18 |
649 |
1.83 |
3.5 |
60 |
77 |
4×16+1×10 |
0.7 |
1.8 |
21 |
965 |
1.15 |
3.5 |
83 |
105 |
4×25+1×16 |
0.9 |
1.8 |
25 |
1456 |
0.727 |
3.5 |
105 |
125 |
4×35+1×16 |
0.9 |
1.8 |
27 |
1863 |
0.524 |
3.5 |
125 |
155 |
4×50+1×25 |
1 |
1.9 |
29 |
2633 |
0.387 |
3.5 |
160 |
185 |
4×70+1×35 |
1.1 |
2 |
32 |
3565 |
0.268 |
3.5 |
200 |
225 |
4×95+1×50 |
1.1 |
2.1 |
36 |
4735 |
0.193 |
3.5 |
245 |
270 |
4×120+1×70 |
1.2 |
2.3 |
41 |
5977 |
0.153 |
3.5 |
285 |
310 |
4×150+1×70 |
1.4 |
2.4 |
44 |
7276 |
0.124 |
3.5 |
325 |
345 |
4×185+1×95 |
1.6 |
2.5 |
49 |
9055 |
0.0991 |
3.5 |
375 |
390 |
4×240+1×120 |
1.7 |
2.7 |
54 |
11567 |
0.0754 |
3.5 |
440 |
450 |
4×300+1×150 |
1.8 |
3.1 |
66 |
14321 |
0.0601 |
3.5 |
505 |
515 |
We generally believe that one’s character decides products’ excellent, the details decides products’ good quality ,with all the REALISTIC,EFFICIENT AND INNOVATIVE group spirit for New Delivery for 0.6/1kv Electric Aluminum Conductor PVC/XLPE/PE Insulated PVC Sheathed Low/Medium Voltag Electrical Power Cable, We warmly welcome merchants from home and abroad to call us and establish business relationship with us, and we will do our best to serve you.
New Delivery for China Power Cable and Electrical Power Cable, Our qualified engineering team will usually be prepared to serve you for consultation and feedback. We have been able to also deliver you with absolutely free samples to meet your needs. Best efforts might be made to offer you the ideal service and products and solutions. For anyone who is interested in our company and items, you should make contact with us by sending us emails or contact us right away. In order to know our solutions and organization. ar more, you can come to our factory to determine it. We’ve been gonna usually welcome guests from around the globe to our corporation. o create small business relations with us. You should definitely feel no cost to speak to us for enterprise. nd we believe we’re likely to share the most effective trading practical experience with all our merchants.