Supply OEM Multi Copper Conductor PVC Sheathed Installation Building Wire for Sale 450/750V Rubber Flexible Cable H07rn-F 3G1.5 3G2.5 Sq. mm Copper Cable
While in the past few years, our organization absorbed and digested sophisticated technologies both equally at home and abroad. Meanwhile, our corporation staffs a group of experts devoted to your advancement of Supply OEM Multi Copper Conductor PVC Sheathed Installation Building Wire for Sale 450/750V Rubber Flexible Cable H07rn-F 3G1.5 3G2.5 Sq. mm Copper Cable, We are seeking forward to receiving your enquiries soon.
While in the past few years, our organization absorbed and digested sophisticated technologies both equally at home and abroad. Meanwhile, our corporation staffs a group of experts devoted to your advancement of China Fan Installation Electrical Wires and Catenary Wire Electrical Installation, We take measure at any price to attain essentially the most up-to-date gear and procedures. The packing of nominated brand is our a further distinguishing feature. The solutions to assure years of trouble-free service has attracted a great deal customers. The goods are obtainable in improved designs and richer variety, they’re produced scientifically of purely raw supplies. It accessible in a variety of designs and specifications for the selection. The newest forms are much far better than the previous one and they’re extremely popular with several clients.
Application
These cables are designed to provide high flexibility and have the capacity to withstand weather, oil/grease, mechanical and thermal stresses. Applications include handling equipment, mobile power supplies, worksites, stage and audio visual equipment, port areas and dams. The cables are used in drainage and water treatment, cold environments and severe industrial environments. Also used as electrical connect line or wiring in power installation, household appliances, electrically operated tools, instruction lighting and machines inner rated voltage A.C 450/750V or below.
Constrution
Characteristics
Rated voltage(U0/U) | 450/750V |
Insulation material | Rubber compound |
Sheath material | Rubber compound(CPE) |
Permissible continuous working temperature |
Not exceed 60°C |
Test voltage | 2500 volts |
Flexing bending radius | 6 x Ø |
Fixed bending radius | 4.0 x Ø |
Flexing Temperature | 25ºC to +60ºC |
Fixed Temperature | 40ºC to +60ºC |
Short circuit temperature | +200ºC |
Insulation resistance | 20 MΩ x km |
Cross sectional area | 1.5mm2- 400mm2 |
Cores | 1core; 2 core; 3core; 4core; 5core; 3+1core |
Parameters
1 Core H07rn-f Rubber Cable |
||||||||
Size |
Nominal Insulation Thickness |
Minimum Insulation Thickness |
Nominal Jacket Thickness |
Minimum Jacket Thickness |
Nominal Overall Diameter ±8% |
Approx. Cable Weight |
Nominal Current ar air temp. 30°C |
|
mm2 |
mm |
mm |
mm |
mm |
mm |
KG/KM |
Mobile |
Fixed |
1×1.5 |
0.8 |
0.7 |
1.4 |
1.1 |
5.8 |
52 |
16.5 |
23 |
1×2.5 |
0.9 |
0.7 |
1.4 |
1.1 |
6.3 |
66 |
22 |
32 |
1×4 |
1 |
0.7 |
1.5 |
1.2 |
7.2 |
89 |
30 |
43 |
1×6 |
1 |
0.7 |
1.6 |
1.3 |
7.9 |
113 |
38 |
56 |
1×10 |
1.2 |
1 |
1.8 |
1.4 |
9.5 |
170 |
53 |
77 |
1×16 |
1.2 |
1 |
1.9 |
1.5 |
10.6 |
229 |
71 |
102 |
1×25 |
1.4 |
1.2 |
2 |
1.6 |
12.4 |
327 |
94 |
136 |
1×35 |
1.4 |
1.2 |
2.2 |
1.8 |
13.8 |
422 |
117 |
168 |
1×50 |
1.6 |
1.3 |
2.4 |
1.9 |
16 |
583 |
148 |
203 |
1×70 |
1.6 |
1.3 |
2.6 |
2.1 |
17.8 |
763 |
185 |
254 |
1×95 |
1.8 |
1.5 |
2.8 |
2.3 |
20.2 |
1003 |
222 |
299 |
1×120 |
1.8 |
1.5 |
3 |
2.5 |
22.1 |
1222 |
260 |
363 |
1×150 |
2 |
1.7 |
3.2 |
2.6 |
24.3 |
1497 |
300 |
416 |
1×185 |
2.2 |
1.9 |
3.4 |
2.8 |
26.6 |
1822 |
341 |
475 |
1×240 |
2.4 |
2.1 |
3.5 |
2.9 |
29.4 |
2298 |
407 |
559 |
1×300 |
2.6 |
2.2 |
3.6 |
3 |
32.2 |
2816 |
468 |
637 |
1×400 |
2.8 |
2.4 |
3.8 |
3.1 |
35.9 |
3615 |
468 |
637 |
2 Core H07rn-f Rubber Cable |
||||||||
Size |
Nominal Insulation Thickness |
Minimum Insulation Thickness |
Nominal Jacket Thickness |
Minimum Jacket Thickness |
Nominal Overall Diameter ±8% |
Approx. Cable Weight |
Nominal Current ar air temp. 30°C |
|
mm2 |
mm |
mm |
mm |
mm |
mm |
KG/KM |
Mobile |
Fixed |
2×1.0 |
0.8 |
0.6 |
1.3 |
1 |
8 |
96 |
10 |
18 |
2×1.5 |
0.8 |
0.6 |
1.5 |
1.2 |
8.9 |
122 |
16 |
23 |
2×2.5 |
0.9 |
0.7 |
1.7 |
1.3 |
10.5 |
172 |
25 |
32 |
2×4 |
1.0 |
0.8 |
1.8 |
1.4 |
12 |
233 |
34 |
43 |
2×6 |
1.0 |
0.8 |
2.0 |
1.6 |
13.4 |
299 |
43 |
56 |
2×10 |
1.2 |
1.0 |
3.1 |
2.5 |
18.2 |
538 |
60 |
77 |
2×16 |
1.2 |
1.0 |
3.3 |
2.7 |
20.4 |
709 |
79 |
102 |
2×25 |
1.4 |
1.2 |
3.6 |
3.0 |
24.3 |
1021 |
105 |
136 |
2×35 |
1.4 |
1.2 |
3.8 |
3.1 |
26.7 |
1275 |
130 |
168 |
2×50 |
1.6 |
1.3 |
4.2 |
3.5 |
31.1 |
1758 |
160 |
203 |
2×70 |
1.6 |
1.3 |
4.6 |
3.8 |
34.7 |
2269 |
196 |
254 |
2×95 |
1.8 |
1.5 |
5.0 |
4.2 |
39.5 |
2978 |
238 |
299 |
3 Core H07rn-f Rubber Cable |
||||||||
Size |
Nominal Insulation Thickness |
Minimum Insulation Thickness |
Nominal Jacket Thickness |
Minimum Jacket Thickness |
Nominal Overall Diameter ±8% |
Approx. Cable Weight |
Nominal Current ar air temp. 30°C |
|
mm2 |
mm |
mm |
mm |
mm |
mm |
KG/KM |
Mobile |
Fixed |
3×1.0 |
0.8 |
0.6 |
1.4 |
1.1 |
8.6 |
115 |
10 |
18 |
3×1.5 |
0.8 |
0.6 |
1.6 |
1.3 |
9.6 |
146 |
16 |
23 |
3×2.5 |
0.9 |
0.7 |
1.8 |
1.4 |
11.2 |
206 |
25 |
32 |
3×4 |
1.0 |
0.8 |
1.9 |
1.5 |
12.8 |
282 |
35 |
43 |
3×6 |
1.0 |
0.8 |
2.1 |
1.7 |
14.3 |
363 |
44 |
56 |
3×10 |
1.2 |
1.0 |
3.3 |
2.7 |
19.5 |
654 |
60 |
77 |
3×16 |
1.2 |
1.0 |
3.5 |
2.9 |
21.9 |
870 |
82 |
102 |
3×25 |
1.4 |
1.2 |
3.8 |
3.1 |
26.0 |
1257 |
109 |
136 |
3×35 |
1.4 |
1.2 |
4.1 |
3.4 |
28.8 |
1593 |
135 |
168 |
3×50 |
1.6 |
1.3 |
4.5 |
3.7 |
33.4 |
2198 |
169 |
203 |
3×70 |
1.6 |
1.3 |
4.8 |
4.0 |
37.1 |
2832 |
211 |
254 |
3×95 |
1.8 |
1.5 |
5.3 |
4.4 |
42.4 |
3747 |
250 |
299 |
3×120 |
1.8 |
1.5 |
5.6 |
4.7 |
46.2 |
4528 |
290 |
263 |
3×150 |
2.0 |
1.7 |
6.0 |
5.0 |
50.9 |
5549 |
332 |
416 |
4 Core H07rn-f Rubber Cable |
||||||||
Size |
Nominal Insulation Thickness |
Minimum Insulation Thickness |
Nominal Jacket Thickness |
Minimum Jacket Thickness |
Nominal Overall Diameter ±8% |
Approx. Cable Weight |
Nominal Current ar air temp. 30°C |
|
mm2 |
mm |
mm |
mm |
mm |
mm |
KG/KM |
Mobile |
Fixed |
4×1.0 |
0.8 |
0.6 |
1.5 |
1.2 |
9.5 |
141 |
10 |
16 |
4×1.5 |
0.8 |
0.6 |
1.7 |
1.3 |
10.5 |
179 |
16 |
21 |
4×2.5 |
0.9 |
0.7 |
1.9 |
1.5 |
12.3 |
253 |
20 |
29 |
4×4 |
1.0 |
0.8 |
2 |
1.6 |
14.1 |
348 |
30 |
38 |
4×6 |
1.0 |
0.8 |
2.3 |
1.9 |
15.9 |
457 |
37 |
50 |
4×10 |
1.2 |
1.0 |
3.4 |
2.8 |
21.2 |
797 |
52 |
68 |
4×16 |
1.2 |
1.0 |
3.6 |
3.0 |
23.8 |
1068 |
69 |
92 |
4×25 |
1.4 |
1.2 |
4.1 |
3.4 |
28.8 |
1580 |
92 |
122 |
4×35 |
1.4 |
1.2 |
4.4 |
3.6 |
31.8 |
2004 |
114 |
150 |
4×50 |
1.6 |
1.3 |
4.8 |
4.0 |
36.9 |
2766 |
143 |
282 |
4×70 |
1.6 |
1.3 |
5.2 |
4.3 |
41.1 |
3592 |
178 |
232 |
4×95 |
1.8 |
1.5 |
5.9 |
4.9 |
47.3 |
4799 |
210 |
281 |
4×120 |
1.8 |
1.5 |
6.0 |
5.0 |
51.2 |
5739 |
246 |
325 |
4×150 |
2.0 |
1.7 |
6.5 |
5.4 |
56.5 |
7060 |
280 |
373 |
4×185 |
2.2 |
1.9 |
7 |
5.9 |
62.1 |
8613 |
330 |
424 |
4×240 |
2.4 | 2.1 | 7.7 | 6.4 | 69.8 | 11025 | 408 | 480 |
5 Core H07rn-f Rubber Cable |
||||||||
Size |
Nominal Insulation Thickness |
Minimum Insulation Thickness |
Nominal Jacket Thickness |
Minimum Jacket Thickness |
Nominal Overall Diameter ±8% |
Approx. Cable Weight |
Nominal Current ar air temp. 30°C |
|
mm2 |
mm |
mm |
mm |
mm |
mm |
KG/KM |
Mobile |
Fixed |
5×1.0 |
0.8 |
0.6 |
1.6 |
1.3 |
10.5 |
173 |
10 |
16 |
5×1.5 |
0.8 |
0.6 |
1.8 |
1.4 |
11.6 |
218 |
16 |
21 |
5×2.5 |
0.9 |
0.7 |
2.0 |
1.6 |
13.5 |
308 |
20 |
29 |
5×4 |
1.0 |
0.8 |
2.2 |
1.8 |
15.7 |
432 |
30 |
38 |
5×6 |
1.0 |
0.8 |
2.5 |
2.0 |
17.6 |
566 |
38 |
50 |
5×10 |
1.2 |
1.0 |
3.6 |
3.0 |
23.3 |
970 |
54 |
68 |
5×16 |
1.2 |
1.0 |
3.9 |
3.2 |
26.4 |
1316 |
71 |
92 |
5×25 |
1.4 |
1.2 |
4.4 |
3.6 |
31.8 |
1943 |
94 |
122 |
5×35 |
1.4 |
1.2 |
4.6 |
3.8 |
34.9 |
2444 |
114 |
150 |
5×50 |
1.6 |
1.3 |
5.2 |
4.3 |
40.9 |
3420 |
143 |
182 |
5×70 |
1.6 |
1.3 |
5.7 |
4.7 |
45.7 |
4462 |
178 |
232 |
5×95 |
1.8 |
1.5 |
6.3 |
5.3 |
52.3 |
5914 |
210 |
281 |
5×120 |
1.8 |
1.5 |
6.3 |
5.3 |
56.4 |
7050 |
246 |
325 |
5×150 |
2.0 |
1.7 |
6.8 |
5.7 |
62.2 |
8668 |
280 |
373 |
While in the past few years, our organization absorbed and digested sophisticated technologies both equally at home and abroad. Meanwhile, our corporation staffs a group of experts devoted to your advancement of Supply OEM Multi Copper Conductor PVC Sheathed Installation Building Wire for Sale 450/750V Rubber Flexible Cable H07rn-F 3G1.5 3G2.5 Sq. mm Copper Cable, We are seeking forward to receiving your enquiries soon.
Supply OEM China Fan Installation Electrical Wires and Catenary Wire Electrical Installation, We take measure at any price to attain essentially the most up-to-date gear and procedures. The packing of nominated brand is our a further distinguishing feature. The solutions to assure years of trouble-free service has attracted a great deal customers. The goods are obtainable in improved designs and richer variety, they’re produced scientifically of purely raw supplies. It accessible in a variety of designs and specifications for the selection. The newest forms are much far better than the previous one and they’re extremely popular with several clients.