Supply OEM/ODM 4 Core XLPE Insulated PVC Sheathed Unarmoured Power Cable/ Flexible Flame Retardant Power Cable
We’ve a qualified, efficiency group to offer excellent support for our client. We normally follow the tenet of customer-oriented, details-focused for Supply OEM/ODM 4 Core XLPE Insulated PVC Sheathed Unarmoured Power Cable/ Flexible Flame Retardant Power Cable, Currently, we are seeking ahead to even bigger cooperation with abroad buyers determined by mutual benefits. Please sense absolutely free to contact us for more details.
We’ve a qualified, efficiency group to offer excellent support for our client. We normally follow the tenet of customer-oriented, details-focused for China Copper Cable and PVC Insulated Copper, By adhering to the principle of “human oriented, winning by quality”, our company sincerely welcomes merchants from at home and abroad to visit us, talk business with us and jointly create a brilliant future.
Application
Indoors cable trunking, outdoors for power stations, industry and switchgear as well as for urban supply networks, if mechanical damage is unlikely
Constrution
Characteristics
Rated voltage: 0.6/1kV
1.during normal operation of cable, the maximum conductor temperature shall be 70℃ for PVC insulation and 90℃ for XLPE insulation.
2.Maximum temperature of conductor during short circuit (maximum duration not exceeding 5 seconds) : PVC insulation — 160℃ for conductor cross section ≤300mm2, 140℃ for conductor cross section > 300mm2; Crosslinked PVC insulation at 250℃.
3.When laying cables, the ambient temperature shall not be less than 0℃, and the minimum allowable bending radius is as follows:
Single core cable: unarmored 20D, armored 15D
Multi-core cable: 15D for unarmored, 12D for armored
Where: D- actual outer diameter of cable.
4.Cable breaking force:
Aluminum core cable: 40×S (N)
Copper core cable: 70×S (N)
Note: S is the total cross-sectional area of the conductor
Standards
IEC 60502-1, GB/T 12706.1
Parameters
Single Core Power Cable |
||||||||
Nom. Cross-section of conductor |
Insulation Thickness |
Sheath Thickness |
Approx. O.D. |
Approx Weight |
Max. D.C. Resistance of Conductor (20°C) |
Test Voltage A.C |
Current Rating |
|
mm2 |
mm |
mm |
mm |
kg/km |
Ω/km |
kV/5min |
In air(A) |
In soil(A) |
1×1.5 |
0.7 |
1.4 |
6 |
53 |
12.1 |
3.5 |
22 |
33 |
1×2.5 |
0.7 |
1.4 |
6 |
68 |
7.41 |
3.5 |
31 |
43 |
1×4 |
0.7 |
1.4 |
7 |
87 |
4.61 |
3.5 |
41 |
56 |
1×6 |
0.7 |
1.4 |
7 |
110 |
3.08 |
3.5 |
52 |
70 |
1×10 |
0.7 |
1.4 |
8 |
155 |
1.83 |
3.5 |
71 |
94 |
1×16 |
0.7 |
1.4 |
9 |
220 |
1.15 |
3.5 |
92 |
120 |
1×25 |
0.9 |
1.4 |
10 |
345 |
0.727 |
3.5 |
120 |
155 |
1×35 |
0.9 |
1.4 |
12 |
424 |
0.524 |
3.5 |
150 |
185 |
1×50 |
1 |
1.4 |
13 |
555 |
0.387 |
3.5 |
180 |
220 |
1×70 |
1.1 |
1.4 |
14 |
770 |
0.268 |
3.5 |
230 |
270 |
1×95 |
1.1 |
1.5 |
16 |
1040 |
0.193 |
3.5 |
285 |
320 |
1×120 |
1.2 |
1.5 |
18 |
1290 |
0.153 |
3.5 |
335 |
365 |
1×150 |
1.4 |
1.6 |
20 |
1590 |
0.124 |
3.5 |
385 |
410 |
1×185 |
1.6 |
1.6 |
22 |
1944 |
0.0991 |
3.5 |
450 |
465 |
1×240 |
1.7 |
1.7 |
25 |
2510 |
0.0754 |
3.5 |
535 |
540 |
1×300 |
1.8 |
1.8 |
27 |
3042 |
0.0601 |
3.5 |
620 |
610 |
1×400 |
2 |
1.9 |
31 |
3869 |
0.047 |
3.5 |
720 |
695 |
1×500 |
2.2 |
2.1 |
35 |
4910 |
0.0366 |
3.5 |
835 |
780 |
1×630 |
2.4 |
2.2 |
40 |
6220 |
0.0283 |
3.5 |
960 |
880 |
1×800 |
2.6 |
2.4 |
45 |
7870 |
0.0221 |
3.5 |
1110 |
970 |
1×1000 |
2.8 |
2.6 |
51 |
9804 |
0.0176 |
3.5 |
1230 |
1060 |
2 Core Power Cable |
||||||||
Nom. Cross-section of conductor |
Insulation Thickness |
Sheath Thickness |
Approx. O.D. |
Approx Weight |
Max. D.C. Resistance of Conductor (20°C) |
Test Voltage A.C |
Current Rating |
|
mm2 |
mm |
mm |
mm |
kg/km |
Ω/km |
kV/5min |
In air(A) |
In soil(A) |
2×2.5 |
0.7 |
1.8 |
11.8 |
151 |
7.41 |
3.5 |
26 |
35 |
2×4 |
0.7 |
1.8 |
12.7 |
198 |
4.61 |
3.5 |
34 |
45 |
2×6 |
0.7 |
1.8 |
13.7 |
250 |
3.08 |
3.5 |
43 |
57 |
2×10 |
0.7 |
1.8 |
15 |
374 |
1.83 |
3.5 |
60 |
77 |
2×16 |
0.7 |
1.8 |
17 |
518 |
1.15 |
3.5 |
83 |
105 |
2×25 |
0.9 |
1.8 |
20 |
772 |
0.727 |
3.5 |
105 |
125 |
2×35 |
0.9 |
1.8 |
22 |
1006 |
0.524 |
3.5 |
125 |
155 |
2×50 |
1 |
1.8 |
20 |
1365 |
0.387 |
3.5 |
160 |
185 |
2×70 |
1.1 |
1.8 |
21 |
1872 |
0.268 |
3.5 |
200 |
225 |
2×95 |
1.1 |
1.8 |
24 |
2475 |
0.193 |
3.5 |
245 |
270 |
2×120 |
1.2 |
1.8 |
27 |
3089 |
0.153 |
3.5 |
285 |
310 |
2×150 |
1.4 |
1.9 |
30 |
3834 |
0.124 |
3.5 |
325 |
345 |
3 Core Power Cable |
||||||||
Nom. Cross-section of conductor |
Insulation Thickness |
Sheath Thickness |
Approx. O.D. |
Approx Weight |
Max. D.C. Resistance of Conductor (20°C) |
Test Voltage A.C |
Current Rating |
|
mm2 |
mm |
mm |
mm |
kg/km |
Ω/km |
kV/5min |
In air(A) |
In soil(A) |
3×1.5 |
0.7 |
1.5 |
10 |
145 |
12.1 |
3.5 |
20 |
27 |
3×2.5 |
0.7 |
1.5 |
11 |
185 |
7.41 |
3.5 |
26 |
35 |
3×4 |
0.7 |
1.5 |
12 |
250 |
4.61 |
3.5 |
34 |
45 |
3×6 |
0.7 |
1.5 |
13 |
320 |
3.08 |
3.5 |
43 |
57 |
3×10 |
0.7 |
1.8 |
16 |
450 |
1.83 |
3.5 |
60 |
77 |
3×16 |
0.7 |
1.8 |
18 |
640 |
1.15 |
3.5 |
83 |
105 |
3×25 |
0.9 |
1.8 |
21 |
940 |
0.727 |
3.5 |
105 |
125 |
3×35 |
0.9 |
1.8 |
23 |
1260 |
0.524 |
3.5 |
125 |
155 |
3×50 |
1 |
1.8 |
23 |
1670 |
0.387 |
3.5 |
160 |
185 |
3×70 |
1.1 |
1.8 |
26 |
2280 |
0.268 |
3.5 |
200 |
225 |
3×95 |
1.1 |
1.9 |
30 |
3020 |
0.193 |
3.5 |
245 |
270 |
3×120 |
1.2 |
2 |
32 |
3790 |
0.153 |
3.5 |
285 |
310 |
3×150 |
1.4 |
2.2 |
37 |
4750 |
0.124 |
3.5 |
325 |
345 |
3×185 |
1.6 |
2.3 |
41 |
5654 |
0.0991 |
3.5 |
375 |
390 |
3×240 |
1.7 |
2.4 |
46 |
7243 |
0.0754 |
3.5 |
440 |
450 |
3×300 |
1.8 |
2.6 |
51 |
9465 |
0.0601 |
3.5 |
505 |
515 |
3×400 |
2 |
3 |
64 |
12066 |
0.047 |
3.5 |
570 |
575 |
4 Core Power Cable |
||||||||
Nom. Cross-section of conductor |
Insulation Thickness |
Sheath Thickness |
Approx. O.D. |
Approx Weight |
Max. D.C. Resistance of Conductor (20°C) |
Test Voltage A.C |
Current Rating |
|
mm2 |
mm |
mm |
mm |
kg/km |
Ω/km |
kV/5min |
In air(A) |
In soil(A) |
4×4 |
0.7 |
1.8 |
13 |
253 |
4.61 |
3.5 |
34 |
45 |
4×6 |
0.7 |
1.8 |
14 |
337 |
3.08 |
3.5 |
43 |
57 |
4×10 |
0.7 |
1.8 |
17 |
501 |
1.83 |
3.5 |
60 |
77 |
4×16 |
0.7 |
1.8 |
20 |
778 |
1.15 |
3.5 |
83 |
105 |
4×25 |
0.9 |
1.8 |
23 |
1160 |
0.727 |
3.5 |
105 |
125 |
4×35 |
0.9 |
1.8 |
25 |
1554 |
0.524 |
3.5 |
125 |
155 |
4×50 |
1 |
1.8 |
23 |
2148 |
0.387 |
3.5 |
160 |
185 |
4×70 |
1.1 |
1.8 |
27 |
2928 |
0.268 |
3.5 |
200 |
225 |
4×95 |
1.1 |
1.9 |
31 |
3854 |
0.193 |
3.5 |
245 |
270 |
4×120 |
1.2 |
2 |
33 |
4925 |
0.153 |
3.5 |
285 |
310 |
4×150 |
1.4 |
2.2 |
38 |
6238 |
0.124 |
3.5 |
325 |
345 |
4×185 |
1.6 |
2.3 |
42 |
7562 |
0.0991 |
3.5 |
375 |
390 |
4×240 |
1.7 |
2.5 |
47 |
9836 |
0.0754 |
3.5 |
440 |
450 |
4×300 |
1.8 |
2.6 |
52 |
12550 |
0.0601 |
3.5 |
505 |
515 |
4×400 |
2 |
3.1 |
66 |
15929 |
0.047 |
3.5 |
570 |
575 |
5 Core Power Cable |
||||||||
Nom. Cross-section of conductor |
Insulation Thickness |
Sheath Thickness |
Approx. O.D. |
Approx Weight |
Max. D.C. Resistance of Conductor (20°C) |
Test Voltage A.C |
Current Rating |
|
mm2 |
mm |
mm |
mm |
kg/km |
Ω/km |
kV/5min |
In air(A) |
In soil(A) |
5×4 |
0.7 |
1.8 |
14.5 |
349 |
4.61 |
3.5 |
34 |
45 |
5×6 |
0.7 |
1.8 |
15.8 |
460 |
3.08 |
3.5 |
43 |
57 |
5×10 |
0.7 |
1.8 |
19 |
699 |
1.83 |
3.5 |
60 |
77 |
5×16 |
0.7 |
1.8 |
22 |
1013 |
1.15 |
3.5 |
83 |
105 |
5×25 |
0.9 |
1.8 |
25 |
1566 |
0.727 |
3.5 |
105 |
125 |
5×35 |
0.9 |
1.9 |
28 |
2083 |
0.524 |
3.5 |
125 |
155 |
5×50 |
1 |
2 |
31 |
2921 |
0.387 |
3.5 |
160 |
185 |
5×70 |
1.1 |
2.1 |
36 |
3974 |
0.268 |
3.5 |
200 |
225 |
5×95 |
1.1 |
2.2 |
39 |
5297 |
0.193 |
3.5 |
245 |
270 |
5×120 |
1.2 |
2.4 |
44 |
6638 |
0.153 |
3.5 |
285 |
310 |
5×150 |
1.4 |
2.5 |
49 |
8290 |
0.124 |
3.5 |
325 |
345 |
5×185 |
1.6 |
2.7 |
55 |
10215 |
0.0991 |
3.5 |
375 |
390 |
5×240 |
1.7 |
3 |
64 |
13130 |
0.0754 |
3.5 |
440 |
450 |
5×300 |
1.8 |
3.2 |
70 |
16670 |
0.0601 |
3.5 |
505 |
515 |
3+1 Core Power Cable |
||||||||
Nom. Cross-section of conductor |
Insulation Thickness |
Sheath Thickness |
Approx. O.D. |
Approx Weight |
Max. D.C. Resistance of Conductor (20°C) |
Test Voltage A.C |
Current Rating |
|
mm2 |
mm |
mm |
mm |
kg/km |
Ω/km |
kV/5min |
In air(A) |
In soil(A) |
3×4+1×2.5 |
0.7 |
1.8 |
13 |
236 |
4.61 |
3.5 |
34 |
45 |
3×6+1×4 |
0.7 |
1.8 |
14 |
316 |
3.08 |
3.5 |
43 |
57 |
3×10+1×6 |
0.7 |
1.8 |
17 |
461 |
1.83 |
3.5 |
60 |
77 |
3×16+1×10 |
0.7 |
1.8 |
19 |
679 |
1.15 |
3.5 |
83 |
105 |
3×25+1×16 |
0.9 |
1.8 |
22 |
1065 |
0.727 |
3.5 |
105 |
125 |
3×35+1×16 |
0.9 |
1.8 |
24 |
1360 |
0.524 |
3.5 |
125 |
155 |
3×50+1×25 |
1 |
1.8 |
25 |
1901 |
0.387 |
3.5 |
160 |
185 |
3×70+1×35 |
1.1 |
1.9 |
28 |
2585 |
0.268 |
3.5 |
200 |
225 |
3×95+1×50 |
1.1 |
2 |
32 |
3518 |
0.193 |
3.5 |
245 |
270 |
3×120+1×70 |
1.2 |
2.1 |
35 |
4443 |
0.153 |
3.5 |
285 |
310 |
3×150+1×70 |
1.4 |
2.2 |
40 |
5326 |
0.124 |
3.5 |
325 |
345 |
3×185+1×95 |
1.6 |
2.4 |
43 |
8501 |
0.0991 |
3.5 |
375 |
390 |
3×240+1×120 |
1.7 |
2.5 |
48 |
11155 |
0.0754 |
3.5 |
440 |
450 |
3×300+1×150 |
1.8 |
2.7 |
54 |
14470 |
0.0601 |
3.5 |
505 |
515 |
3×400+1×240 |
2 |
3.1 |
66 |
309 |
0.047 |
3.5 |
570 |
575 |
3+2 Core Power Cable |
||||||||
Nom. Cross-section of conductor |
Insulation Thickness |
Sheath Thickness |
Approx. O.D. |
Approx Weight |
Max. D.C. Resistance of Conductor (20°C) |
Test Voltage A.C |
Current Rating |
|
mm2 |
mm |
mm |
mm |
kg/km |
Ω/km |
kV/5min |
In air(A) |
In soil(A) |
3×4+2×2.5 |
0.7 |
1.8 |
13.9 |
413 |
4.61 |
3.5 |
34 |
45 |
3×6+2×4 |
0.7 |
1.8 |
15.3 |
6682 |
3.08 |
3.5 |
43 |
57 |
3×10+2×6 |
0.7 |
1.8 |
18 |
603 |
1.83 |
3.5 |
60 |
77 |
3×16+2×10 |
0.7 |
1.8 |
21 |
888 |
1.15 |
3.5 |
83 |
105 |
3×25+2×16 |
0.9 |
1.8 |
24 |
1342 |
0.727 |
3.5 |
105 |
125 |
3×35+2×16 |
0.9 |
1.8 |
26 |
1647 |
0.524 |
3.5 |
125 |
155 |
3×50+2×35 |
1 |
1.9 |
29 |
2386 |
0.387 |
3.5 |
160 |
185 |
3×70+2×35 |
1.1 |
2 |
32 |
3201 |
0.268 |
3.5 |
200 |
225 |
3×95+2×50 |
1.1 |
2.1 |
36 |
4269 |
0.193 |
3.5 |
245 |
270 |
3×120+2×70 |
1.2 |
2.3 |
41 |
5437 |
0.153 |
3.5 |
285 |
310 |
3×150+2×70 |
1.4 |
2.4 |
44 |
6519 |
0.124 |
3.5 |
325 |
345 |
3×185+2×95 |
1.6 |
2.5 |
49 |
8101 |
0.0991 |
3.5 |
375 |
390 |
3×240+2×120 |
1.7 |
2.7 |
54 |
10340 |
0.0754 |
3.5 |
440 |
450 |
3×300+2×150 |
1.8 |
2.8 |
56 |
12810 |
0.0601 |
3.5 |
505 |
515 |
4+1 Core Power Cable |
||||||||
Nom. Cross-section of conductor |
Insulation Thickness |
Sheath Thickness |
Approx. O.D. |
Approx Weight |
Max. D.C. Resistance of Conductor (20°C) |
Test Voltage A.C |
Current Rating |
|
mm2 |
mm |
mm |
mm |
kg/km |
Ω/km |
kV/5min |
In air(A) |
In soil(A) |
4×4+1×2.5 |
0.7 |
1.8 |
14.5 |
331 |
4.61 |
3.5 |
34 |
45 |
4×6+1×4 |
0.7 |
1.8 |
15.9 |
435 |
3.08 |
3.5 |
43 |
57 |
4×10+1×6 |
0.7 |
1.8 |
18 |
649 |
1.83 |
3.5 |
60 |
77 |
4×16+1×10 |
0.7 |
1.8 |
21 |
965 |
1.15 |
3.5 |
83 |
105 |
4×25+1×16 |
0.9 |
1.8 |
25 |
1456 |
0.727 |
3.5 |
105 |
125 |
4×35+1×16 |
0.9 |
1.8 |
27 |
1863 |
0.524 |
3.5 |
125 |
155 |
4×50+1×25 |
1 |
1.9 |
29 |
2633 |
0.387 |
3.5 |
160 |
185 |
4×70+1×35 |
1.1 |
2 |
32 |
3565 |
0.268 |
3.5 |
200 |
225 |
4×95+1×50 |
1.1 |
2.1 |
36 |
4735 |
0.193 |
3.5 |
245 |
270 |
4×120+1×70 |
1.2 |
2.3 |
41 |
5977 |
0.153 |
3.5 |
285 |
310 |
4×150+1×70 |
1.4 |
2.4 |
44 |
7276 |
0.124 |
3.5 |
325 |
345 |
4×185+1×95 |
1.6 |
2.5 |
49 |
9055 |
0.0991 |
3.5 |
375 |
390 |
4×240+1×120 |
1.7 |
2.7 |
54 |
11567 |
0.0754 |
3.5 |
440 |
450 |
4×300+1×150 |
1.8 |
3.1 |
66 |
14321 |
0.0601 |
3.5 |
505 |
515 |
We’ve a qualified, efficiency group to offer excellent support for our client. We normally follow the tenet of customer-oriented, details-focused for Supply OEM/ODM 4 Core XLPE Insulated PVC Sheathed Unarmoured Power Cable/ Flexible Flame Retardant Power Cable, Currently, we are seeking ahead to even bigger cooperation with abroad buyers determined by mutual benefits. Please sense absolutely free to contact us for more details.
Supply OEM/ODM China Copper Cable and PVC Insulated Copper, By adhering to the principle of “human oriented, winning by quality”, our company sincerely welcomes merchants from at home and abroad to visit us, talk business with us and jointly create a brilliant future.