0.6/1kv CU/XLPE/PVC Steel Tape Armoured Cable

Short Description:

Conductor: Copper

Insulation: XLPE

Insulation Color: Red, Blue, Grey, Yellow/Green or as request

Rated Voltage: 0.6/1KV

Jacket: PVC

Standard: IEC, UL, GB, JIS, GS, ASTM

 

Email: sales@zhongweicables.com

Acceptance: OEM/ODM, Trade, Wholesale, Regional Agency

Payment: T/T, L/C, PayPal

Stock Sample is Free & Available

Product Detail

Product Tags

Application

Xlpe insulated pvc sheathed steel tape armoured Cable is composed of pure copper conductor, XLPE insulation, steel tape armor, and flame-retardant PVC sheath. Multicore industrial cables are suitable for 0.6/1KV rated voltage, able to withstand certain mechanical gravity, which can be used for power stations, subway, tunnels, high-rise buildings, large industrial and mining enterprises, oil fields, coal mines, and other places of intensive distributed electric cables.

Constrution

Characteristics

Rated voltage: 0.6 / 1 kV

Maximum Conductor Temperature: under normal (90℃), emergency (130℃) or short circuit no more than 5 s (250℃) conditions.

Min. Ambient Temp. 0℃, after installation and only when cable is in a fixed position

Min. Bending Radius: 12 x cable O.D for multi core

Standards

IEC 60502-1, GB/T 12706.1

Parameters

2 Core Steel Tape Armoured Cable

Nom. Cross-section of conductor

Insulation Thickness

Inner Covering Thickness

Steel Tape Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

2×4

0.7

1.2

2×0.2

1.8

15

433

4.61

3.5

34

45

2×6

0.7

1.2

2×0.2

1.8

16

500

3.08

3.5

43

57

2×10

0.7

1.2

2×0.2

1.8

19

673

1.83

3.5

60

77

2×16

0.7

1.4

2×0.2

1.8

21

857

1.15

3.5

83

105

2×25

0.9

1.4

2×0.2

1.8

24

1173

0.727

3.5

105

125

2×35

0.9

1.6

2×0.2

1.8

25

1449

0.524

3.5

125

155

2×50

1

1.6

2×0.2

1.8

26

1877

0.387

3.5

160

185

2×70

1.1

1.8

2×0.2

1.8

27

2454

0.268

3.5

200

225

2×95

1.1

1.8

2×0.2

1.9

30

2483

0.193

3.5

245

270

2×120

1.2

2

2×0.2

2

33

4213

0.153

3.5

285

310

2×150

1.4

2

2×0.5

2.2

38

5087

0.124

3.5

325

345

3 Core Steel Tape Armoured Cable

Nom. Cross-section of conductor

Insulation Thickness

Inner Covering Thickness

Steel Tape Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

3×1.5

0.7

1

2×0.2

1.5

13

273

12.1

3.5

20

27

3×2.5

0.7

1

2×0.2

1.5

14

321

7.41

3.5

26

35

3×4

0.7

1.2

2×0.2

1.5

15

390

4.61

3.5

34

45

3×6

0.7

1.2

2×0.2

1.5

16

471

3.08

3.5

43

57

3×10

0.7

1.4

2×0.2

1.5

18

622

1.83

3.5

60

77

3×16

0.7

1.4

2×0.2

2

22

1005

1.15

3.5

83

105

3×25

0.9

1.6

2×0.2

2

25

1371

0.727

3.5

105

125

3×35

0.9

1.6

2×0.2

2

27

1724

0.524

3.5

125

155

3×50

1

1.8

2×0.2

2

30

2247

0.387

3.5

160

185

3×70

1.1

1.8

2×0.2

2.5

35

3023

0.268

3.5

200

225

3×95

1.1

2

2×0.5

2.5

39

3825

0.193

3.5

245

270

3×120

1.2

2

2×0.5

2.5

42

4642

0.153

3.5

285

310

3×150

1.4

2

2×0.5

3

48

5767

0.124

3.5

325

345

3×185

1.6

2.2

2×0.5

3

51

6895

0.0991

3.5

375

390

3×240

1.7

2.2

2×0.5

3

56

8617

0.0754

3.5

440

450

3×300

1.8

2.2

2×0.5

3

59

10928

0.0601

3.5

505

515

3×400

2

2.2

2×0.5

3.2

61

13556

0.047

3.5

570

575

4 Core Steel Tape Armoured Cable

Nom. Cross-section of conductor

Insulation Thickness

Inner Covering Thickness

Steel Tape Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

4×4

0.7

1

2×0.2

1.5

16

454

4.61

3.5

34

45

4×6

0.7

1

2×0.2

1.5

17

557

3.08

3.5

43

57

4×10

0.7

1

2×0.2

2

20

791

1.83

3.5

60

77

4×16

0.7

1

2×0.2

2

23

1210

1.15

3.5

83

105

4×25

0.9

1

2×0.2

2

27

1672

0.727

3.5

105

125

4×35

0.9

1

2×0.2

2

29

2127

0.524

3.5

125

155

4×50

1

1

2×0.2

2

33

2802

0.387

3.5

160

185

4×70

1.1

1.2

2×0.2

2.5

38

3785

0.268

3.5

200

225

4×95

1.1

1.2

2×0.5

2.5

42

4829

0.193

3.5

245

270

4×120

1.2

1.4

2×0.5

3

47

6033

0.153

3.5

285

310

4×150

1.4

1.4

2×0.5

3

52

7356

0.124

3.5

325

345

4×185

1.6

1.6

2×0.5

3

56

8806

0.0991

3.5

375

390

4×240

1.7

1.6

2×0.5

3

62

11182

0.0754

3.5

440

450

4×300

1.8

1.7

2×0.5

3.1

64

14176

0.0601

3.5

505

515

4×400

2

1.7

2×0.5

3.5

69

17815

0.047

3.5

570

575

5 Core Steel Tape Armoured Cable

Nom. Cross-section of conductor

Insulation Thickness

Inner Covering Thickness

Steel Tape Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

5×4

0.7

1

2×0.2

1.5

17.1

588

4.61

3.5

34

45

5×6

0.7

1

2×0.2

1.5

19.4

720

3.08

3.5

43

57

5×10

0.7

1

2×0.2

2

22.9

1014

1.83

3.5

60

77

5×16

0.7

1

2×0.2

2

25.8

1392

1.15

3.5

83

105

5×25

0.9

1

2×0.2

2

30.5

2002

0.727

3.5

105

125

5×35

0.9

1

2×0.2

2

33.7

2581

0.524

3.5

125

155

5×50

1

1

2×0.5

2

38.6

3722

0.387

3.5

160

185

5×70

1.1

1.2

2×0.5

2.5

43.4

4897

0.268

3.5

200

225

5×95

1.1

1.2

2×0.5

2.5

48.6

6338

0.193

3.5

245

270

5×120

1.2

1.4

2×0.5

3

54.4

7851

0.153

3.5

285

310

5×150

1.4

1.4

2×0.5

3

60.1

9661

0.124

3.5

325

345

5×185

1.6

1.6

2×0.5

3

66.7

11770

0.0991

3.5

375

390

5×240

1.7

1.6

2×0.5

3

74.7

14900

0.0754

3.5

440

450

5×300

1.8

1.7

2×0.5

3.1

83.2

18000

0.0601

3.5

505

515

3+1 Core Steel Tape Armoured Cable

Nom. Cross-section of conductor

Insulation Thickness

Inner Covering Thickness

Steel Tape Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

3×4 + 1×2.5

0.7

1

2×0.2

1.5

16

443

4.61

3.5

34

45

3×6 + 1×4

0.7

1

2×0.2

1.5

17

531

3.08

3.5

43

57

3×10 + 1×6

0.7

1

2×0.2

2

20

741

1.83

3.5

60

77

3×16 + 1×10

0.7

1

2×0.2

2

23

1135

1.15

3.5

83

105

3×25 + 1×16

0.9

1

2×0.2

2

26

1556

0.727

3.5

105

125

3×35 + 1×16

0.9

1

2×0.2

2

28

1896

0.524

3.5

125

155

3×50 + 1×25

1

1

2×0.2

2

31

2518

0.387

3.5

160

185

3×70 + 1×35

1.1

1.2

2×0.2

2.5

36

3293

0.268

3.5

200

225

3×95 + 1×50

1.1

1.2

2×0.5

2.5

40

4349

0.193

3.5

245

270

3×120 + 1×70

1.2

1.2

2×0.5

2.5

44

5365

0.153

3.5

285

310

3×150 + 1×70

1.4

1.4

2×0.5

3

49

6468

0.124

3.5

325

345

3×185 + 1×95

1.6

1.4

2×0.5

3

52

7854

0.0991

3.5

375

390

3×240 + 1×120

1.7

1.6

2×0.5

3.5

68

9814

0.0754

3.5

440

450

3×300 + 1×150

1.8

1.7

2×0.5

3.5

71

12781

0.0601

3.5

505

515

3×400 + 1×240

2

1.7

2×0.5

3.5

76

16359

0.047

3.5

570

575

3+2 Core Steel Tape Armoured Cable

Nom. Cross-section of conductor

Insulation Thickness

Inner Covering Thickness

Steel Tape Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

3×4 + 2×2.5

0.7

1

2×0.2

1.5

17.5

855

4.61

3.5

34

45

3×6 + 2×4

0.7

1

2×0.2

1.5

18.9

1009

3.08

3.5

43

57

3×10 + 2×6

0.7

1

2×0.2

2

21.6

1461

1.83

3.5

60

77

3×16 + 2×10

0.7

1

2×0.2

2

24.6

1877

1.15

3.5

83

105

3×25 + 2×16

0.9

1

2×0.2

2

28.7

2583

0.727

3.5

105

125

3×35 + 2×16

0.9

1

2×0.2

2

30.7

3001

0.524

3.5

125

155

3×50 + 2×35

1

1

2×0.2

2

36.2

4392

0.387

3.5

160

185

3×70 + 2×35

1.1

1.2

2×0.2

2.5

40.3

5519

0.268

3.5

200

225

3×95 + 2×50

1.1

1.2

2×0.5

2.5

44.9

7543

0.193

3.5

245

270

3×120 + 2×70

1.2

1.2

2×0.5

2.5

50.3

9203

0.153

3.5

285

310

3×150 + 2×70

1.4

1.4

2×0.5

3

54

10485

0.124

3.5

325

345

3×185 + 2×95

1.6

1.4

2×0.5

3

60.2

13945

0.0991

3.5

375

390

3×240 + 2×120

1.7

1.6

2×0.5

3.5

67.2

15643

0.0754

3.5

440

450

3×300 + 2×150

1.8

1.7

2×0.5

3.5

75.2

18204

0.0601

3.5

505

515

4+1 Core Steel Tape Armoured Cable

Nom. Cross-section of conductor

Insulation Thickness

Inner Covering Thickness

Steel Tape Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

4×4 + 1×2.5

0.7

1

2×0.2

1.5

18.4

565

4.61

3.5

34

45

4×6 + 1×4

0.7

1

2×0.2

1.5

19.8

692

3.08

3.5

43

57

4×10 + 1×6

0.7

1

2×0.2

2

22.8

953

1.83

3.5

60

77

4×16 + 1×10

0.7

1

2×0.2

2

25.8

1318

1.15

3.5

83

105

4×25 + 1×16

0.9

1

2×0.2

2

30.4

1877

0.727

3.5

105

125

4×35 + 1×16

0.9

1

2×0.2

2

34.1

2324

0.524

3.5

125

155

4×50 + 1×25

1

1

2×0.2

2

38.7

3415

0.387

3.5

160

185

4×70 + 1×35

1.1

1.2

2×0.5

2.5

44.2

4432

0.268

3.5

200

225

4×95 + 1×50

1.1

1.2

2×0.5

2.5

49.8

5747

0.193

3.5

245

270

4×120 + 1×70

1.2

1.2

2×0.5

2.5

55.4

7112

0.153

3.5

285

310

4×150 + 1×70

1.4

1.4

2×0.5

3

60.1

8556

0.124

3.5

325

345

4×185 + 1×95

1.6

1.4

2×0.5

3

66.9

10510

0.0991

3.5

375

390

4×240 + 1×120

1.7

1.6

2×0.5

3.5

74.8

13232

0.0754

3.5

440

450

4×300 + 1×150

1.8

1.7

2×0.5

3.5

78.4

16452

0.0601

3.5

Packing & Shipping

FAQ

Q: Can we have our logo or company name to be printed on your products or the package?
A: The OEM & ODM order is warmly welcome and we have fully successful experience in OEM projects. What's more, our R&D team will give you the professional suggestions.
Q: What’s the payment terms?
A: 30% T/T deposit, 70% T/T balance payment before shipment.
Q: How does your factory do regarding quality control?
A: We have a strict quality control system, and our professional experts will check the appearance and test functions of all our items before shipment.
Q: How can I get a sample to test your quality?
A: We can provide free samples for your test and checking, just need to bear the freight charge.

Contact us for more informations about our products, our professional team will serve you and customized according to your requirements.


  • Previous:
  • Next:

  • Armoured Cable Xlpe
  • Pvc Armoured Cable
  • Steel Tape Armored Cable
  • Steel Tape Armoured Cable
  • Xlpe Armoured Cable
  • Write your message here and send it to us